Design and Test Technology of High Temperature Environmental Chamber Sales
1. Temperature selection
(1) The climatic zones of the region; Whether the product is exposed to the solar radiation environment near the heating device; Surrounding air, solar radiation and ways of heat transfer from heating devices to products; The actual technical state of the product (open or shaded).
(2)Use similar product temperature. Similar products refer to those with similar USES, performance and installation locations, such as upgrading products
2. The conditions of environmental chamber sales
(1) High-temperature storage
Thermostatic storage: after the sample reaches temperature stability (the temperature of internal components, components, modules, components, etc., also reaches stability) in the high-temperature environment, it can be maintained for at least 2 hours, and the longest can be 48 hours. If the storage time is over 48 hours, the temperature stability time will be included.
Cyclic storage: at least 7 cycles (24h for one cycle). If the key material or high temperature sensitive material is affected by high temperature environment, the cycle number should be increased appropriately.
(2) Hot operation in environmental chamber sales
Thermostatic work: after samples reached the stable in high temperature working environment(judgment methods: the differences of the internal heat of samples of the largest feature or key components should be less than 2 ℃ per hour , If the temperature of the internal element (part) cannot be measured, the temperature time shall be determined according to the thermal analysis to ensure that the temperature of the whole sample is stable)keep it at least 2 h, and then let the sample work, and make it on the specified working temperature to achieve stability, began to test the functionality and performance. After the test is completed, the sample will stop working and the air temperature in the box will be adjusted to the standard atmospheric conditions. After reaching the stability under the standard atmospheric conditions, the overall appearance, function and performance will be tested.
3. Temperature monitoring in environmental chambers
When monitoring the test temperature, the position of the temperature sensor should ensure that the influence of thermal diffusion is negligible, and pay attention to avoid the influence of thermal radiation.
関連推奨品
-
Chemical synthesis process control system temperature control system TCU
1121Today, let's talk about our DCS integrated control system (temperature and other control of synthetic process). Scalability: the system is an open system, which provides standard TCP / P data communication interface protocol, interface software an...
詳細を見る -
グリコールチラーを設置する際の注意点は?
1015夏場はグリコール・チラーの使用頻度が比較的高い。そのため、グリコール・チラーを設置する際には、平滑で整頓された床に設置する必要がある。なぜ滑らかな地面を選ぶのか?グリコール冷凍機を知っているユーザー...
詳細を見る -
Description of heat sink characteristics in chip temperature control
1288With the continuous development of electronic chips, its heat dissipation technology is also advancing. LNEYA chip temperature control technology is continuously promoted along with chip test equipment. The development trend of modern computer chi...
詳細を見る -
Common faults of plate heat exchangers in new energy vehicle inspection
1380The reason for the excessive pressure drop of the new energy vehicle detection is that the running system pipeline is not properly purged, especially in the newly installed system pipeline, many dirt (such as welding slag) enters the interior of t...
詳細を見る