グリコールチラーを設置する際の注意点は?
In the summer, the use of glycol chillers
is relatively frequent. Therefore, when installing glycol chillers, they need
to be installed on a smooth and tidy floor. Why choose a smooth ground when
installing? Users who have known the glycol chiller should know that if the
glycol chiller is tilted during installation, it may cause the refrigerant or
cooling water or chilled water to operate abnormally, and the refrigerant may
flow backward or the resistance may increase, which is not conducive to The
normal operation of the refrigeration system.
The glycol chiller can run the compressor
on a stable surface to make the compressor run more efficiently. Because the
normal operation of each component of the compressor takes into account the
gravity problem, the smooth ground can avoid the resistance of the liquid
medium in the flow or the acceleration of gravity, and the glycol chiller can
be operated more efficiently.
Of course, the noise problem is also
plaguing many users of glycol chillers. In fact, the flat ground can
effectively reduce the vibration and noise during operation, because the flat
ground can reduce the vibration during operation, which is beneficial to its
ethylene glycol. Silence effect to enhance its service life.
If the glycol chiller is operated on a
non-flat floor, due to the effect of gravity, the probability of loosening and
peeling off under the vibration generated by the
operation of the glycol chiller is greater.The user can install it according to
the requirements.
LNEYA low temperature circulator has a wide
refrigeration temperature range, and the controllable temperature is – 150 ° C to – 5 ° C.
Secondary subcooling is adopted, which has fast cooling speed, safety and
reliability. It is used for rapid liquid cooling. It is widely used in
petrochemical, medical, pharmaceutical, biochemical, freeze-drying,
pharmaceutical and other high-tech industries. A single compressor can achieve
– 152 ℃ temperature control, and the ultra-low temperature refrigeration
technology is at the international advanced level. To save water resources,
ethylene glycol water mixture can be used for circulating refrigeration, and
the design of circulating pipeline shall be strict to prevent circulating water
pollution and prolong the service time of circulating water; Overlapping
subcooling refrigeration technology.
関連推奨品
-
LNEYA PCRマイクロ流体チップ温度制御システムプロジェクト開発の客観性
1030PCRマイクロ流体チップ温度制御システムは、LNEYAが集積回路チップ業界向けに製造した新しい動的冷凍加熱装置です。LNEYA社製PCRマイクロ流体チップ温度制御システムは、チップ検査業界向けに開発された新しい動的冷凍加熱システムです。
詳細を見る -
Purchasing Strategy of Ultra-low Temperature Freezer
949The performance of refrigeration system determines the overall performance. If refrigeration technology is good, excellent refrigeration effect can be achieved quickly. It takes only 4-5 hours on average from room temperature to minus 8 degrees Ce...
詳細を見る -
The entry point for the selection of industrial chillers
1090Industrial chillers are refrigeration devices that assemble refrigerators, condensers, evaporators, expansion valves, control systems, and switch boxes on a common base or frame. According to the heat rejection method of the unit, it can be divide...
詳細を見る -
高温・低温液体循環式冷凍機の氷詰まりに対応する小型クーラー
822高温および低温の液体循環式冷凍機の運転において、氷詰まりは比較的よく見られる故障です。関連メーカーの経験に基づき、氷詰まりに対処するためのヒントを特別にまとめました。配管内の...
詳細を見る