Ultra Low Temp Chiller Compressor Common Protection Instructions
について ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let’s take a look!
The most common protection for ultra low temp chiller compressors is the suction and exhaust pressure protection. Basically, each ultra low temp chiller will be equipped with this protection device. The main function of the ultra-low temperature chiller compressor is to take charge of the intake and exhaust, and the working chamber is used to perform compression between the intake and exhaust. The pressure molding of the ultra low temp chiller is installed to prevent the intake and exhaust pressure from being caused. If there is a problem with the suction and exhaust pressure, subsequent operations will not function properly, and ultra low temp chillers will not cool properly.
Then there is the oil pressure difference protection device for the ultra low temp chiller compressor. Some manufacturers install the oil separator when producing the ultra low temp chiller. Therefore, the ultra low temp chiller compressor must have a hydraulic pressure difference protection device. Why? Because the frozen lubricating oil is critical to the compressor of the ultra low temp chiller, and if the frozen lubricating oil is not normal, the compressor will also be abnormal.
In addition to the above-mentioned common faults, other common exhaust temperature protection, which, has the same effect asthe suction and exhaust pressure protection of the ultra low temp chiller compressor, because the inhalation temperature is often not problematic, problems lie in the exhaust temperature. Most of the time, if the exhaust pressure is high, the exhaust temperature will be high. In addition to installing the exhaust pressure protection device, installing the compressor exhaust temperature protection device is actually a two-pronged method. After all, the compressor is more important core components, and there must be no problems.
Of course, the protection configuration of each ultra low temp chiller is also different. Wuxi Guanya also specially sets safety protection devices to protect everyone’s environment.
関連推奨品
-
リニア急速温度変化テスターの空充填手順
1161リニア急速温度変化テスターを始動する前に、防火、保護、漏れ防止、その他のツールなど、関連する保護措置が整っているかどうかを確認します。電源が適切かどうかを確認する。
詳細を見る -
How to choose organic waste gas for condensation treatment?
1248Condensation treatment of organic waste gas equipment is currently used in the environment of environmental protection requirements, then how to choose the organic waste gas equipment for the condensation treatment, how to choose the efficient and...
詳細を見る -
All analysis of refrigerant changing process of industrial chiller unit
997Refrigerant is an indispensable part of the refrigeration system of the industrial chiller. During the operation of the industrial refrigeration unit, the refrigerant constantly changes in the industrial refrigeration unit to achieve the cooling e...
詳細を見る -
Maintenance of vacuum pump for fully enclosed heating and cooling circulator
1125Each accessory in the fully enclosed heating and cooling circulator constitutes the entire refrigeration heating and temperature control system. The performance of the pump is also very important. How to make the maintenance of the pump? For the f...
詳細を見る