ニュース

グリコール・チラーの原理分析
Glycol chiller is an industrial chillerwith glycol as refrigerant. The structure of glycol chiller is roughly the sameas that of ordinary industrial chiller, which is composed of compressor,evaporator, condenser and electric control system. In order to ensure thestable operation of glycol chiller, we suggest that you take explosion-proofmeasures and buy explosion-proof glycol chiller as far as possible.1、 Operation of compressorIn order to ensure that the pressure insidethe evaporat...
詳細を見る
グリコールチラーの動作原理
For the low-temperature chiller using ethylene glycol solution, wecall it glycol chiller. Its outlet water temperature is generally below - 10 ℃, and the specific temperature requirements shall be subject to theneeds of users. Glycol chillers are common in chemical plants. In order toensure the safe and stable operation of equipment, many chemical plants willstrictly require water chillers to take explosion-proof measures, that is, whatwe often call explosion-proof water chillers.The str...
詳細を見る
冷暖房サーモスタットの誤作動を防ぐには?
When the user is running the heating and cooling thermostat, the operation needs to follow the instructions, so how to avoid inappropriate operations? Excellent design of hot and cold thermostat: The LNEYA heating and cooling thermostat has a multi-functional alarm system and safety functions. It uses plate heat exchangers and pipeline heaters to increase heating and cooling rates. Large touch screen graphics display. The heating and cooling integrated machine uses a magnetic drive pump, so ...
詳細を見る
工業用冷水機の基本構造
Basic structure of industrial water chiller:Industrial water chiller consists ofcompressor, condenser, evaporator, expansion valve and other accessories.1. Compressor: in the industrial water chillersystem, the compressor is the power to ensure refrigeration. The compressor isused to increase the pressure of the refrigerant in the system and make therefrigerant circulate in the refrigeration system to achieve the purpose ofrefrigeration.2. Condenser: high temperature and highpressure...
詳細を見る
工業用冷水機の分類と用途
In lots ofindustrial production processes, it is difficult to obtain high efficientindustrial production efficiency if there is no industrial water chiller toprovide a low temperature production environment. Therefore, industrial water chilleris a very important and professional refrigeration equipment in the industrialmarket. At present, industrial water chillers can be divided into a lot oftypes, and their application range is also wide. So, what kinds of industrial waterchiller s...
詳細を見る
工業用恒温循環式冷凍機の特徴
Points for attention in the use ofindustrial constant temperature recirculating chillerIndustrial constant temperature recirculatingchillers are widely used in pharmaceutical, chemical and laboratory. Next,let's introduce the characteristics, application scope and application methodsof industrial recirculating chillers in detail.The industrial constant temperaturerecirculating chiller can have the functions of heating and cooling at the sametime. It can cool or heat or maintain const...
詳細を見る
How to use a multimeter to test the components of the chip test temperature control machine?
The chip test temperature controller is used for IC, CPU, GPU, DPU, BGA, FCBGA, LGA, QFN, QFP, CSP, WLCSP, Bare Die, and other Device Under Test. So, how to use a multimeter for these commonly used components What about testing? For electronic components such as transformers, deflection coils, compensation inductors, etc., since the resistance of the inductive components wound by the wire is very low, it is difficult to detect short-circuit faults; open-circuit faults depend on the resistance...
詳細を見る
グリコールチラーシステムを長持ちさせるには?
In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points· 1. Use automobile grade antifreeze carefullyDo not use automobile grade or unqualified antifreeze. Because this glycol is not manufactured for industrial applications, it may cause a variety of problems and shorten the service life of your glycol chiller system. 2. Comply with local regulations.Experts have designed different rules and regulations according to t...
詳細を見る
工業用冷水機の水ポンプの機能
The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don't know much about the equipment. This time, lneya refrigeration will talk about the role of the water pump of the industrial water chiller. The function of the water pump of the industrial water chiller is to provide pressure and water flow according to the needs of the system. The chilled water pum...
詳細を見る
工業用冷水機の一般的な故障のトラブルシューティング
As we all know, with the rapid development of modern industrial technology, in order to improve production efficiency, improve product quality and reduce consumption costs, the demand for temperature control equipment in the process is higher and higher, but there are more and more product quality problems about some industrial water chillers, So we simply analyze some common problems about industrial water chillers. Abnormal temperature at the inlet and outlet of cooling water: the water tem...
詳細を見る