有機廃ガス精製凝縮シャットダウンノート
有機性排ガスを精製・凝縮した場合、運転中に故障が発生すれば、その時点で運転を停止して廃棄しなければなりません。では、一度停止した有機廃ガス精製・濃縮装置はどのように使用できるのでしょうか。その...
The organic waste gas purification condensing device introduces the volatile VOCS gas into the equipment cold box (the device sets the condensation temperature 3 ° C -40 ° C -75 ° C -115 ° C). Other temperature zones can be customized to follow the demand for gradual condensation liquefaction. Part of the continuous production process has done a two-way switching process in the low temperature section (after one side of the ice block, it is directly switched to another heat exchange cold box condensation, while the ice block side is treated with defrost). With the increasing attention to environmental issues, organic waste gas purification and condensation is favored by customers.
Once the machine is shut down, if the exhaust gas high pressure of the organic exhaust gas purification and condensation is solved, after the low water temperature fault is removed, if it is not solved, it is necessary to press the reset operation of the protection switch, and then the power is turned on after the shutdown switch. If the shut-off valve cannot be easily closed after tripping, the motor cannot be started directly across the current interrupter. The motor and wiring that require organic exhaust gas purification and condensation should be inspected in detail to find out the cause of the trip and how to deal with it. Just fine.
If you want to stop the organic exhaust gas purification and condensation operation under a relatively normal state, it is recommended that you do not stop the power supply directly. Remember to keep the oil heater in a state of constant heating during the shutdown state. Ultra-low voltage faults as well as high-temperature faults and flow faults are automatically reset after being eliminated. Once the auto-reset is required, the shutdown switch can be pressed again before it can be restarted, so that the organic exhaust gas purification and condensation can be operated more efficiently.
The organic waste gas purification condensing shutdown needs to be cautious. If the shutdown is improper, it may cause some failures. Therefore, the user needs to know clearly before proceeding.

関連推奨品
-
Discussion on maintenance of high and low temperature integrated cycle machine
1155LNEYA high and low temperature integrated cycle machine is a refrigeration heating equipment produced by the use of refrigeration heating dynamic temperature control technology. The temperature range is from -120 °C to 350 °C. It has superior perf...
詳細を見る -
Start-up work for new energy thermal management
998In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
詳細を見る -
Precautions for changing the refrigerating oil in the cooling system of the car charger
808The cooling system of the car charger should pay attention to the condition of the refrigerating oil during the operation. After the compressor is started, carefully observe the changes in the oil temperature and oil pressure. If the oil changes c...
詳細を見る -
触媒水素化プロセスにおける温度加熱・冷却サイクルの必要性
1111In recent years, with the rising price of oil, the demand for benzene obtained from coking benzene has increased, coupled with the country's increasing emphasis on environmental protection, the widespread application of coking benzene hydrogenatio...
詳細を見る