Discussion on maintenance of high and low temperature integrated cycle machine
LNEYA high and low temperature integrated cycle machine is a refrigeration heating equipment produced by the use of refrigeration heating dynamic temperature control technology. The temperature range is from -120 °C to 350 °C. It has superior performance, high precision and intelligent temperature control. It needs regular time when used. Do a good job of maintenance.
The high and low temperature integrated cycle machine exchanges heat or direct contact heat exchange mode to exchange heat of the medium and cool it through the cooling tower to recycle water to save water resources. In general, the circulating water is neutral and weakly alkaline, and the pH is controlled between 7 and 9.5; in the case of circulating cooling water in direct contact with the medium, it is acidic or alkaline (pH greater than 10.0), generally less.

Always check whether the cooling water pipe is connected safely and securely. Is the flow, temperature and pressure of the cooling water suitable? It is recommended to check the water level of the water tank every month. Once the water level drops, it should be replenished in time and only distilled water can be added. In order to prevent the growth of microorganisms or free organic impurities in the water, so as not to impede the flow of water and affect the cooling effect, it is recommended to add a bactericide in the water, and the distilled water in the water tank is replaced at least once a year. The blades of the air-cooled filter and the cooling fan of the compressor should be cleaned every 6 months. After the cleaning is completed, 12 drops of oil should be added to the fan bearing. In order to reduce the impact of scale on flow and cooling capacity, it is recommended to clean the pipeline every 5 years (if it is cooled with tap water every 2 years).
The high and low temperature integrated cycle machine is very convenient to install and move, but it requires a higher working environment because it is cooled by hot air circulation. Therefore, if the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. In addition, if you want to put the equipment in a dust-free workshop with humidity requirements, then I advise you to modify the water-cooled.
関連推奨品
-
チップテスト専用機TES-5シリーズ準備要領
950The TES-5 series for chip testing is used for electronic component testing. How to accurately detect the chip is very important. So, how much do you know about the test preparation for the TES-5 series for chip testing? Before starting the TES-5 s...
詳細を見る -
液体を100℃に加熱し、30℃に冷却する温度制御システム
1072加熱方法としては、蒸気加熱、熱油加熱などが一般的である。蒸気暖房にはボイラーが必要な場合があり、蒸気が供給される工場に適している。
詳細を見る -
単一流体加熱冷凍システムの温度サイクル故障解析
1081各メーカーの一流体冷暖房システムの性能は異なります。LNEYAでは、冷暖房温度の問題を解決するために、高構成の単一流体冷暖房システムの開発に取り組んでいます。
詳細を見る -
LNEYA精密冷凍機の応用範囲
1191LNEYA精密冷凍機の主な応用産業は、プラスチック産業、電子産業、電気メッキ産業、医療産業、食品産業、真空コーティング産業などです。これらの産業は主な応用産業である。
詳細を見る