In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor.

Under normal working conditions, the compressor of the temperature control system of the reactor should inhale the dry vapor of the refrigerant. There is also lubricating oil entering the cylinder. If there is too much liquid entering, it is too late to discharge from the exhaust valve, and the pressure in the cylinder will rise sharply to form a liquid hammer, which is the damage to the cylinder, valve, piston, connecting rod and other parts. Therefore, various protective measures can be taken for the temperature control system of the reactor, such as installing a gas-liquid separator to separate the liquid entrained in the low-pressure steam to ensure the dry stroke of the compressor; installing an oil heater to lubricate the compressor before starting Oil is added to reduce the amount of refrigerant dissolved in the lubricating oil; or the air valve assembly is pressed against the end of the cylinder with a spring to form a false cover.
In order to ensure that the motor of the temperature control system of the reactor is not overheated, in addition to correct use and attention to maintenance, an overheat relay of the temperature control system of the reactor can also be installed; there is also phase loss protection. If the commonly used three-phase motor is out of phase, it will cause the temperature control of the reactor. If the system motor cannot be started or is overloaded, the overload relay of the reactor temperature control system can be used to avoid damage to the motor due to lack of phase.
The temperature protection method of the exhaust temperature of the reactor temperature control system is mainly to place the thermostat near the exhaust port of the reactor temperature control system. When the exhaust temperature is too high, the thermostat will act to cut off the circuit. If the shell temperature of the reactor temperature control system unit is too high, it will affect the life of the compressor, which is mainly caused by the insufficient heat exchange capacity of the condenser. Therefore, it is necessary to check whether the air volume or water volume and water temperature of the condenser are appropriate. And check whether air or other non-condensable gas is mixed in the refrigeration system of the temperature control system of the reactor, or the suction temperature is too high, etc., you should pay attention to observation and detection.
The operator of the reactor temperature control system should also pay more attention to the maintenance of the compressor to avoid damage.
関連推奨品
-
低温冷凍バスでよくあるデバッグの問題とは?
1383低温冷却槽のデバッグ中、局所冷却効果が悪い場合、異物が詰まっていたり、システム設計に無理があったりして、正常な調整ができないことがあります。このような時、LNEYAが異物を除去し...
詳細を見る -
5P hot and cold water machine installation instructions
1041The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibrati...
詳細を見る -
Cold and hot one mold temperature machine maintenance method description
1217In the process of using the hot and cold integrated mold temperature machine, it is necessary to carry out regular maintenance and repair. Then, LNEYA will share with you the maintenance method of the hot and cold integrated mold temperature machi...
詳細を見る -
化学薬品・医薬品の定温制御syの動作状況を判断する方法
942現在、多くの製薬・化学業界でLNEYAの定温制御システムが採用されています。運転中の運転状態はどのように判断するのでしょうか?製薬・化学用恒温槽のシリンダー内に異音がないこと。
詳細を見る