いつTCU温度制御システムを選択するか?
First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
関連推奨品
-
Is the choice of a centrifugal pump or a volumetric pump in a pharmaceutical laboratory?
1300Performance: In order to be able to select the type of pump that is suitable in the pharmaceutical laboratory, it is necessary to have a deep understanding of its performance and understand the difference in its specific working principle. To this...
詳細を見る -
冷熱機器メーカーのLNEYAです。
1270LNEYA冷凍機メーカーは、冷凍および加熱温度制御システム、超低温冷凍庫、新エネルギー自動車部品試験システム、および加熱サイクルシステムのTOTH研究開発、生産、販売に取り組んでいます。...
詳細を見る -
液冷バッテリーパック AMS冷却システム紹介
857LNEYA液冷バッテリーパックAMS冷却システムは、新エネルギー原料業界の多くのシナリオに適用できます。新エネルギー原料の川中産業では、原料の精製、プロセス温度の制御、冷却...
詳細を見る -
暖房・冷房用サーキュレーターの選択に関する要因は何ですか?
976加熱・冷凍サーキュレーターは、多くの実験室プロジェクトで使用されている。それらは通常、冷却、加熱、温度制御のための反応器やリアクターを備えている。では、どのような要因が加熱・冷却装置の選択に関係しているのでしょうか。
詳細を見る