5P hot and cold water machine installation instructions
The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance?
If the 5P hot and cold water unit refrigeration compressor unit does not have vibration reduction installation, or the vibration reduction effect is not good, according to the installation specifications, the overall vibration damping device should be installed. If the vibration reduction is not standardized or there is no vibration reduction measure, the machine will vibrate severely. It is easy to cause the pipe to crack, 5P hot and cold water machine equipment is damaged, and even other equipment is damaged.
There is no or lack of oil return bend in the refrigerant line of the 5 hot and cold water integrated machines. When the pipeline conveying the refrigerant turns upward from the lateral direction, it must be made into a small bend that is first down and then upwards, that is, a U-bend, so that the 5P hot and cold water integrated machine pipelines are qualified only upwards, and cannot be directly Make a 90 degree steering upward, otherwise the oil in the system can not be returned to the compressor very well, and a large amount of deposition in the equipment, so that 5P hot and cold water machine and the entire system can not function properly, or even damage the equipment .
5P hot and cold water machine integrated machine refrigerant pipeline connection is not balanced, when the unit pipeline is connected to a group of multiple compressors, to make the oil return equal distribution to each compressor, the main pipeline interface must be set at multiple stations. In the middle position of the machine head, then set some branch lines to the two sides to balance the return oil into multiple compressor branch pipes.
The models and designs of the 5P hot and cold water machines of different manufacturers are different. When the LNEYA equipment is issued, the corresponding instruction manual will be attached to give the customer a detailed explanation.

関連推奨品
-
The consequences of the screw refrigerator not returning oil and the treatment method
1201In the cooling operation of the screw refrigerator, if the refrigerant is in contact with the lubricating oil, the lubricating oil in the compressor will enter the condenser with the operation of the refrigeration system and the gaseous or misty r...
詳細を見る -
How to reduce the condensing pressure of the heating circulator unit?
1124During the operation of the heating circulator unit, the temperature change inside the equipment will cause the condensing pressure to change. Especially in summer when the condensing pressure is too high, the power consumption of the compressor w...
詳細を見る -
What are the precautions when choosing an industrial chiller?
814An industrial chiller is a refrigeration device that assembles a refrigerator, condenser, evaporator, expansion valve, control system, and switch box on a common base or frame. According to the heat removal method of the unit, it can be divided in...
詳細を見る -
All analysis of refrigerant changing process of industrial chiller unit
999Refrigerant is an indispensable part of the refrigeration system of the industrial chiller. During the operation of the industrial refrigeration unit, the refrigerant constantly changes in the industrial refrigeration unit to achieve the cooling e...
詳細を見る