LTS -80℃~80℃ Fluoride cooling heating system
- フロー制御12L/min~45L/min
- 温度精度±0.1℃ @-60℃~-30℃
- Internal circulating liquid4L~10L
- 膨張タンク10L~20L
- 原産地中国
製品データダウンロード
製品パラメーター
モデル | LTS-802 | LTS-803 | LTS-804 | LTS-806 | LTS-808 |
LTS-802W | LTS-803W | LTS-804W | LTS-806W | LTS-808W | |
温度範囲 | -80℃~-20℃ | ||||
温度制御精度 | ±0.1℃ -80℃~-50℃ | ||||
フロー制御 | 7~25L/分 | 12~45L/分 | |||
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar. | |||||
Internal circulating fluid volume | 4L | 5L | 6L | 8L | 10L |
膨張タンク容量 | 10L | 10L | 15L | 15L | 20L |
システム圧力表示 | The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure) | ||||
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen | |||||
コントローラー | シーメンスPLC、カスケード制御アルゴリズムによるファジーPID制御アルゴリズム。 | ||||
温度制御 | 熱媒体出口温度制御モード | ||||
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control) | |||||
同意書 | イーサネット・インターフェース TCP/IPプロトコル | ||||
RS485インターフェース modbus RTUプロトコル | |||||
Internal temperature feedback of equipment | Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment) | ||||
閉鎖循環システム | The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system | ||||
コンプレッサー | Emerson Copeland/Danfoss Scroll Flexible Compressor | ||||
循環ポンプ | German brand magnetic circulation pump | ||||
蒸発器 | Adopt Danfoss/Gaoli plate heat exchanger | ||||
コンデンサー | Micro channel condenser (air-cooled) | ||||
Plate heat exchanger (water-cooled), special attention: clean factory water is required | |||||
冷凍アクセサリー | Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve) | ||||
操作パネル | Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export | ||||
セキュリティ | With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions. | ||||
入出力インターフェースサイズ | G1/2 | G1/2 | G3/4 | G3/4 | G3/4 |
商品説明
It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.
1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
温度の見本抽出および応答の速度を、特に設計制御アルゴリズム最大限に活用して下さい、安定した温度調整にすぐに答えることができます。
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.

これらの製品にもご興味があるかもしれません。
MDシリーズチャック
-75℃~225℃ Model MD-708 MD-712 MDL-708 Temp.温度範囲 -75℃~225℃ -75℃~225℃ 温度制御精度 ±0.1℃ ±0.1℃ ±0.1℃ 温度均一性 ±1℃ ±1℃ 平坦度 ±50μm ±50μm 錠剤サイズ 直径 200mm d...
YQH 0℃~-75
様々な揮発性VOCsガスの回収に適し、高速冷却、高効率、さまざまな凝縮温度の要件を満たす、低温は-75℃に達することができる それは主に、洗浄、接着剤、揮発性有機化合物から来る。
FLT-100℃~90
シングルチャンネル空冷式クーラーで、主にエッチングマシン用に設計されています。チャンバー側壁の独立した温度制御に使用されます。
FLTZ -45℃~90
40℃以内の加熱方式はコンプレッサー式ホットガス加熱を採用し、完全密閉設計で、24時間連続運転が可能です。
ロード...
已经是到最后一篇内容了!」。