マイナス80度の超低温フリーザーの使い方
The machine must be tested before usage (or before it is energized again) in the following conditions: when ultra low temperature freezer is first used in ultra low temperature freezer minus 80 degrees, or after the ultra low temperature freezer is moved, or ultra low temperature freezer outages (including power failure) for more than 10 hours. It passes with the qualification certification.
The equipment of ultra low temperature freezer minus 80 degrees can only be powered up after standing in the freezer for at least 24 hours. There is no item in the empty box. After starting the machine, it will be phased into two stages, first to cooling the freezer to minus 40 degrees. Then it should be cooling to minus 60 degrees after formal start and stop. After that, it should be cooling to minus 80 degrees after formally opening and stopping for 8 hours. The cold plate freezer is prove to have normal performance if it can formally start and stop for more than 24 hours.
Items can be stored in the freezer after the operation follows to ultra low temperature freezer minus 80 degrees, which confirms that the freezer is normal. Principally, ultra low temperature freezer minus 80 degrees should stored the items of minus 60 degrees with no more than 1/3 of the box capacity. If the temperature of stored item is higher than minus 60 degrees, the temperature of freezer should be set nearly 3 degrees higher than the item temperature (that is, if the item temperature is 20 degrees, then the temperature of low temperature freezer should be set at 23 degrees) to ensure that the freezer is shut down and has formally started and stopped for 8 hours.
Note: ultra low temperature freezer minus 80 degrees is the equipment for preservation, so it is strictly prohibited to put too much of the relatively too hot items. It will keep the compressor working for a long time. In this condition, the temperature is too high to burn the compressor. And, items must be put in batches. The temperature should be cooling in phases until achieving the required low temperature.
If you want to know about more information besides these instructions of ultra low temperature freezer minus 80 degrees, please directly ask the professional technical personnel of Wuxi Guanya for help, the most reliable one in 超低温冷凍庫メーカー.
関連推奨品
-
半導体製造業界向けデュアル・チャンネル・チラー
969デュアル・チャンネル・チラーは、半導体製造業界の様々なプロセスで使用されています。その主な目的は、半導体製造プロセスの装置が確実に動作するように、正確な温度制御を提供することです。
詳細を見る -
製薬化学産業アプリケーション - 加熱リアクター温度制御
1142医薬化学工業は多くの化学反応を含む。従来の加熱反応器温度制御作業効率は比較的低く、生産コストが比較的高く、装置が比較的面倒である。そのため ...
詳細を見る -
チラーのオイルレベルとオイル差の影響について教えてください。
1164冷凍機メーカーは、冷凍システムに加え、潤滑油システムも重要な部品であり、独自のオイルリザーバーと特殊なオイルクーラーを備えていることを皆に伝えている。したがって、潤滑油の影響を理解する必要がある。
詳細を見る -
バイオリアクター用循環式冷凍機の性能説明
1026The recirculating chiller is suitable forthe high and low temperature reaction of various stainless steel, enamel,titanium alloy reactors, emulsifiers, injection molding machines, mixingvessels and various bioreactors. Other bioreactors in diff...