バイオリアクター用循環式冷凍機の性能説明
The recirculating chiller is suitable for
the high and low temperature reaction of various stainless steel, enamel,
titanium alloy reactors, emulsifiers, injection molding machines, mixing
vessels and various bioreactors. Other bioreactors in different industries are
special recirculating chillers. , Wuxi Guanya LNEYA adopts a fully enclosed
pipeline design, which can achieve higher efficiency in terms of operating
effects.
1. Fully enclosed system
During the operation of the special
recirculating chiller for bioreactor, only the heat transfer medium
participates in the circulation, and the temperature of the expansion tank is
always maintained at room temperature 60℃, which avoids the
problems caused by the air entering the circulation system.
2. High temperature cooling
The compressor can be directly used for
refrigeration at high temperatures (using the single-machine self-cascade
refrigeration technology), and it can be used for high-temperature exothermic
reactions, such as 200 ℃, without changing the medium, only the compressor can control the
temperature and take away excess heat. .
3. Wide temperature range
The special recirculating chiller for
bioreactors can achieve system temperature control in a wide range of -120℃~300℃ with a
single heat transfer medium. However, a single compressor refrigeration
technology can reach a low -150°C, and is smaller in size and easier to lift.
4. Dynamic temperature control technology
The temperature measurement points at the
liquid inlet and outlet and the material will transmit temperature information
in real time. When the temperature difference is large, the control system will
immediately issue an exothermic and endothermic reaction to control the
temperature of the heat transfer medium within ±0.3°C.
5. Pipeline circulation system
Pipeline heaters and plate heat exchangers
increase the power density ratio, reduce the amount of heat transfer medium
used, and improve the response speed of the system’s temperature control.
6. Heating protection
After the control protection of the
controller body fails, if the temperature exceeds the temperature value set by
the deviation protector in the system, the power supply of the solid state
relay will be cut off, and the independent temperature limiter will play its
role after the protector fails. With this triple protection, there will be no
high temperature overshoot.
The quality of equipment manufactured by
different recirculating chiller manufacturers is different, and everyone needs
to be aware of this.
関連推奨品
-
Application of supporting experimental equipment for refrigeration and heating system
1212The mixing tank with jacket and insulation layer is a three-layer insulation mixing tank with heating function, which has the functions of heating, insulation, mixing, etc. It is widely used in dairy, chemical, food, beverage, pharmaceutical, phar...
詳細を見る -
How to troubleshoot the failure of the material aging test chiller?
1059Regular maintenance work for the material aging test chiller, and troubleshooting is also very important. 1. Exhaust at double high pressure, heat dissipation may be problematic. When it is detected that the high and low pressure of the system are...
詳細を見る -
ラボ用グリコールチラーとは?
1205実験室のグリコール・チラーは実験室の commoncooling 装置である。それは一般に冷たい源の温度の条件を達成するのに使用される。1.なぜ実験室のグリコール・チラーを選びなさいか: 単一機械自...
詳細を見る -
超低温冷凍サーキュレーターのメンテナンスのポイント
1113超低温冷凍サーキュレーターは、長期間運転するとメンテナンスが必要になりますが、どのような点に注意すればよいのでしょうか。超低温冷凍サーキュレーターの点検とメンテナンスは定期的に行ってください。それは問題を見つけることができます...
詳細を見る