  1. Wafer cleaning:
  • During the wafer cleaning process, the temperature of the cleaning tank needs to be controlled to ensure the effectiveness of the cleaning solution and the cleanliness of the wafer surface.
  • Dual-channel chillers can control the temperature of different cleaning tanks separately to ensure temperature consistency during the cleaning process.

  1. Etching process:
  • During the etching process, the temperature of the etching chamber needs to be precisely controlled to ensure the etching rate and selectivity.
  • Dual-channel chillers can provide cooling for different parts of the etcher at the same time, such as the etching chamber and the cooling system, to keep the equipment at the optimal operating temperature.

  1. Deposition process:
  • In deposition processes such as chemical vapor deposition (CVD) or physical vapor deposition (PVD), the temperature of the reaction chamber needs to be precisely controlled to ensure the quality and uniformity of the film.
  • The dual-channel chiller can provide precise temperature control for the deposition chamber and cooling system to ensure temperature consistency during the deposition process.

  1. Photolithography process:
  • During the photolithography process, the temperature of the exposure machine needs to be precisely controlled to ensure the exposure characteristics of the photoresist and the accuracy of the pattern.
  • The dual-channel chiller can provide cooling for different parts of the exposure machine, such as the light source system and the mask stage, to keep the equipment at the optimal operating temperature.

  1. Annealing process:
  • During the annealing process, the temperature of the annealing furnace needs to be controlled to ensure the stability of the lattice structure and improve the material properties.
  • The dual-channel chiller can provide cooling for the annealing furnace to ensure the temperature control accuracy during the annealing process.

  1. Ion implantation:
  • During the ion implantation process, the temperature of the ion implanter needs to be precisely controlled to ensure the accuracy of ion implantation and the integrity of the material.
  • The dual-channel chiller can provide cooling for different parts of the ion implanter, such as the ion source and the implantation chamber, to ensure the temperature stability of the equipment.

  1. Packaging process:
  • During the packaging process, the temperature of the packaging equipment needs to be controlled to ensure the curing characteristics of the packaging material and the packaging quality.
  • Dual-channel chillers can provide cooling for different parts of packaging equipment, such as curing ovens and cooling systems, to ensure temperature control accuracy during the packaging process.

  1. Test process:
  • During the test process, the temperature of the test equipment needs to be precisely controlled to ensure the accuracy and consistency of the test results.
  • Dual-channel chillers can provide cooling for different parts of the test equipment, such as test sockets and heat sinks, to ensure temperature consistency during the test process.

  1. Laser cutting equipment:
  • Laser: The temperature of the laser needs to be precisely controlled to ensure the stability and accuracy of the laser output.
  • Cooling system: used to control the internal temperature of the laser cutting machine to ensure stable operation of the equipment.

  1. Chemical Mechanical Polishing (CMP) Equipment:
  • Polishing pad: The temperature of the polishing pad needs to be precisely controlled to ensure temperature consistency during the polishing process.
  • Cooling system: used to control the internal temperature of the CMP equipment to ensure stable operation of the equipment.

  • FLT-100℃~90"      /&gt;<figcaption><span>シングルチャンネル空冷式クーラーで、主にエッチングマシン用に設計されています。チャンバー側壁の独立した温度制御に使用されます。</span></figcaption></figure></a></div><div class=FLT-100℃~90

    シングルチャンネル空冷式クーラーで、主にエッチングマシン用に設計されています。チャンバー側壁の独立した温度制御に使用されます。

    もっと見る
  • FLTZ -45℃~90"      /&gt;<figcaption><span>40℃以内の加熱方式はコンプレッサー式ホットガス加熱を採用し、完全密閉設計で、24時間連続運転が可能です。</span></figcaption></figure></a></div><div class=FLTZ -45℃~90

    40℃以内の加熱方式はコンプレッサー式ホットガス加熱を採用し、完全密閉設計で、24時間連続運転が可能です。