Safety instructions for the use of high temperature circulator heat transfer oil
In order to make the high-temperature circulator run more efficiently, it is recommended to pay attention to the safety and choice of the heat-conducting oil. What should be paid attention to the heat-conducting oil of the high-temperature circulator manufacturer?
Although the high temperature circulator heat transfer oil has a high boiling point and flash point, it is still a flammable liquid. Therefore, it should be safe when used. If it is used improperly, it may cause fire. The cause of the fire is caused by leakage. At this time, attention should be paid to leakage and fire. Related instructions.
Misfire in the insulation zone is a common type of fire in organic heat transfer oil systems. Heat transfer oil leakage occurs at the flange or meter connection, and penetrates into the heat preservation zone. Then, in the presence of air, the circulating liquid and the pipe heat heat the heat transfer oil, and gradually oxidize the liquid, causing the heat preservation zone to be ignited and causing a fire.
Pipe leakage or bursting causes fire due to pipe leakage or bursting, causing heat transfer oil to flow into the hot gas flame zone and causing fire. The flash point causes the flash point to be misfired. The higher the temperature of the high temperature circulator, the lower the flash point temperature, the heat transfer oil, air and fire source.
The fire caused by the process raw materials is mainly caused by the leakage of the heat transfer oil into the heating system, and the process raw materials are easily oxidized and oxidized to cause fire. In addition to the above four types of fire, it should be more careful to use in the gas phase system, such as causing a large amount of heat transfer oil vapor leakage, can form an aerosol mist, which can cause explosive combustion when exposed to fire in the air.
The heat transfer oil of LNEYA high temperature circulators is selected from brand heat transfer oil, because the choice of heat transfer oil is expiring and operating efficiency and safety.

関連推奨品
-
産業用エアチラーの動作原理
1053工業用エアクーラーは、高温の流体を冷却するために空気を使用する熱交換器です。チューブ内の高温流体は、チューブ壁、フィンと、通常換気装置から供給される外気との間の熱交換によって加熱されます。当社のI...
詳細を見る -
データセンターの液冷に対応する冷却ユニットは?
935データセンターの液冷は通常、効率的な熱管理を達成し、サーバーやIT機器が安全な動作温度範囲内で動作することを保証するために、さまざまな冷却装置とマッチします。データセンター液冷用冷却ユニット
詳細を見る -
超低温冷蔵庫のシェル&チューブ・コンデンサーのスケールを除去するには?
1126Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...
詳細を見る -
化学工業における工業用冷水機のデバッグ手順
892化学企業で工業用ウォーターチラーの設置が完了した後、運転の初期段階で一定のデバッグを実施する必要がある。入念なデバッグを行うことで、初めて工業用ウォーターチラーに隠れたトラブルがないかどうかを突き止めることができるのだ。
詳細を見る