13P 半閉鎖式空冷式圧縮コンデンシング・ユニット故障時の注意事項
The 13p semi-closed air-cooled compression condensing unit is used in industrial cold processing. After using it for a long time, some problems will arise, Wuxi Guanya (LNEYA) reminds.
There is usually a high-pressure alarm on the 13p semi-closed air-cooled compression condensing unit, which is automatically activated in the event of an accident. When we start, we will find that there is a fault indicator that is turned off. Because there is a fault now, it lights up. Some smart technologies have a self-protection mechanism. For example, after the high-voltage warning fault light is on, It is no longer running, and it is also to protect the compression condensing unit.
As the operating personnel of the condensing unit, do not force it to open at this time. Instead, check the problem and start the machine after finding the problem. If you can’t find the problem, I suggest you contact the manufacturer’s customer service. According to different situations, the natural solution is different.
The 13p semi-closed air-cooled compression condensing unit is water-cooled and air-cooled. If it is an air-cooled compression condensing unit, the staff should check the ambient temperature used. It is necessary to dispose heat in time because the temperature is too high. it is good. There are also other situations where high pressure alarms occur, and the cooling water flow is too small (this should check if the water valve is open), and the condensing unit should be in an air circulation environment.
If there is a warning state for the water-cooled compression condensing unit, most of them may be due to the failure of the cooling water circulation. If the cooling water valve is not open, if there is no playing card, it will make the water shortage, there is no way to provide condensation. The crew is, of course, sometimes it is also a problem of cooling water. At this time, check if the cooling tower is faulty.
The relevant fault warnings of the compression condensing unit are as shown above. If the relevant faults are found, it is better to solve them in time.

関連推奨品
-
薬物フロー化学プロセス用極低温冷凍機
811医薬品のフローケミストリー(連続製造)プロセスで使用される低温冷凍機は、反応を正確な温度条件下で行うための重要な装置のひとつです。フローケミストリーは連続製造技術です。
詳細を見る -
超低温冷蔵庫のメンテナンスと維持管理
1248超低温冷蔵庫のメンテナンスと保守は、正常な使用とその寿命を延ばすために非常に重要である。温度管理が不正確だと、保護対象物が破損することが多く、その結果、冷蔵庫の寿命が大幅に縮まる。
詳細を見る -
どのようにチラーと射出成形機を選択するには?
1157A.第一の方法:1HP水冷式冷凍機は80トン射出成形機と組み合わせることができ、温度を5-10度に制御することができます。1HP水冷式冷凍機は100トン射出成形機と組み合わせることができ、温度を5-10度に制御することができます。
詳細を見る -
循環式加熱装置用反応釜の運転方法
1093循環加熱装置を備えた実験室用単層ガラス反応器は、反応溶媒を入れたフラスコを内層に置いて攪拌反応させることができ、中間層は定温加熱を実現し、...
詳細を見る