電気自動車部品試験用冷却水循環装置の膨張弁の説明
The demand for electric vehicle parts testing cooling water circulation machine in the testing of new energy vehicle battery industry is rising, so the choice is very important. Among them, the expansion valve is a more important accessory, and we also need to understand its performance.

The electronic expansion valve of the cooling water circulation machine for electric vehicle parts testing mainly consists of four parts. The rotor is equivalent to the rotor of a synchronous motor, and the valve stem is connected to control the opening of the valve hole. The stator is equivalent to the stator of synchronous electronics; it converts electrical energy into a magnetic field. Drive the rotor to rotate, the valve needle is driven by the rotor, the end is tapered, and moves up and down to adjust the flow rate. The valve body is generally made of brass.
Electronic expansion valve suction superheat control, suction superheat control system is composed of electronic expansion valve, pressure sensor, temperature sensor and controller. When working, the pressure sensor will evaporator outlet pressure P1 and the temperature sensor will suck the compressor through The heat is transmitted to the controller, and the controller processes the signal, and then outputs a command to act on the stepper motor of the electronic expansion main valve to open the valve to the required position.
It takes only a few seconds for the electronic expansion valve to change from fully closed to fully open. The reaction and action speed is fast. The opening and closing characteristics and speed can be set manually; the electronic expansion valve can be adjusted within a specific range and the adjustment range It can be set according to the characteristics of different products.
When testing and installing electronic expansion valves for electric vehicle parts, the centerline of the valve body and coil section should be taken as the axis, and the coil should be upward. When welding the electronic expansion valve and the filter screen, the valve body needs to be cooled and protected, so that the temperature of the valve body does not exceed 120°C, and to prevent impurities from entering the valve body. In addition, the flame should not be directed at the valve body, and at the same time, nitrogen should be filled into the valve body to prevent the generation of oxides. The output voltage of the controller must be consistent with the specified voltage of the coil. If the applied voltage does not match the specified voltage, the coil will burn out or the valve needle will act abnormally.
Before installing the expansion valve, please refer to the installation guide provided by the manufacturer to avoid unnecessary failures.
関連推奨品
-
The Advantages Of The Industrial Chiller For Cascade Cryogenic Refrigeration System
1327Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system...
詳細を見る -
Vocs 凝縮分離装置膨張弁メンテナンス説明書
927一旦、凝縮分離装置の膨張弁が故障すると、その解決策が間に合わなければ、凝縮分離装置全体が使用できなくなる可能性がある。そのため、凝縮分離装置の膨張弁の故障は、凝縮分離装置全体が使用できなくなる可能性がある。
詳細を見る -
流体温度制御装置のチップテスト回路設計
1242With the continuous development of the domestic chip industry, LNEYA fluid temperature control devices continue to be applied. To this end, the circuit design for the fluid temperature control device chip test, the fluid temperature control device...
詳細を見る -
グリコールチラーを設置する際の注意点は?
1023夏場はグリコール・チラーの使用頻度が比較的高い。そのため、グリコール・チラーを設置する際には、平滑で整頓された床に設置する必要がある。なぜ滑らかな地面を選ぶのか?グリコール冷凍機を知っているユーザー...
詳細を見る