Once the expansion valve of the vocs condensing and separating device fails, if the solution is not solved in time, the entire vocs condensing and separating device may be unavailable. Therefore, the failure of the expansion valve of the vocs condensing separation device needs to be solved in time, and attention is paid to maintenance.
Before servicing the expansion valve, it is necessary to observe whether the expansion valve is normally closed. The ability to open and close the expansion valve in time means that the vocs condensing separation device is used normally, and can quickly reduce the ambient temperature in a short time. Conversely, if there is a fault in the expansion valve, then the pressure inside the vocs condensing separation device appears to be high or low. If the vocs condensing separation device expansion valve failure is not handled in time, the operational safety of the vocs condensing separation device will be affected, even jeopardized. To the company’s normal use of vocs condensation separation equipment.
In order to protect the vocs condensing separation equipment evaporator and expansion valve, in order to avoid the impact of the vocs condensing separation equipment operating power is affected, the company needs regular maintenance of the expansion valve and evaporator. It can eliminate the common faults of vocs condensation separation equipment in time, and clean up the surface and internal components of vocs condensation separation equipment, which can prolong the service life of vocs condensation separation equipment and create conditions for reducing the cost of vocs condensation separation equipment.
The vocs condensing separation equipment expansion valve blockage is a frequent occurrence, the main cause of dirty plugging is the presence of impurities in the system, such as welding slag, copper filings, iron filings, fibers and so on. The reason for ice blockage is that the system contains too much moisture (moisture). For light ice blockage, hot towel can be applied to the ice block. If the ice blockage is serious and has affected the normal operation of the system, it should be replaced. Filter the dryer, re-discharge the water in the system piping, evacuate, and refill the refrigerant.
It should be noted that the expansion valve of the vocs condensing separation equipment can be solved by contacting the vocs condensing separation equipment manufacturer if it cannot be solved during installation and maintenance.

関連推奨品
-
高温と低温の冷却恒温システムを維持するには?
937The high and low temperature cooling constant temperature system performs refrigeration and heating operation in the pharmaceutical and chemical industry. It follows the rules of operation and meticulous requirements to continuously improve its qu...
詳細を見る -
超低温循環式冷凍機をより省エネにする方法
1071現代では、環境保護と省エネが開発テーマであり、工業用冷凍機も同様である。では、工業用チラーをより省エネにするにはどうすればいいのでしょうか?まず、工業用冷凍機の配管スケールを防止・低減する。
詳細を見る -
Explosion-proof high temperature and low temperature machine factory note
1243Explosion-proof high and low temperature integrated machine is the main product of LNEYA production and sales. It adopts dynamic temperature control system and fully closed pipeline design. The operation effect is relatively stable. What common pr...
詳細を見る -