What are the maintenance of glycol chillers in daily operation?
In the daily operation of the glycol chiller, if the maintenance is not in place, the cooling effect will be reduced. Therefore, in order to improve the operating efficiency, we recommend that you carry out the necessary daily maintenance.
Refrigeration system inspection: Generally, after long-term use of ethylene glycol chillers, various problems will inevitably occur. In the event of a failure, the use of each part of the machine should be carefully checked, focusing on the refrigeration system, electrical system, air system and water system to determine whether their functions are normal. We usually examine them by sound and appearance. If there is a problem, it is recommended to replace it in time.
Refrigerant inspection: Regularly check whether the refrigerant of the glycol chiller leaks: It can be determined by referring to the parameters displayed by the high and low pressure meter on the front panel of the main unit. According to the temperature change of the air temperature (winter and summer), the pressure display of the glycol chiller is also different. When the low temperature chiller is working normally, the high pressure shows 11-17kg, and the low pressure shows 3-5kg.
Cooling water system inspection: It is normal to check whether the cooling water system of the ethylene glycol chiller is normal, whether the cooling water tower fan and water spray shaft are in good operation, and whether the water supply in the built-in water tank of the chiller is normal.
System cleaning: Glycol chillers should be cleaned annually after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good cooling effect.
Voltage and current inspection: Regularly check whether the voltage and current of the glycol chiller are stable and whether the compressor is running normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
The above aspects are some of the areas that require routine maintenance. Of course, there are many other details that need your attention.
関連推奨品
-
化学冷凍・加熱循環システム使用上の注意事項
1041化学薬品製造では、反応により熱が発生し、熱ムラが生じます。排出が間に合わないと、釜の温度が上昇して危険な状態になる。既存の原子炉の加熱システムは、熱のムラが発生しやすい。
詳細を見る -
LNEYA低温チラーの開発
946経済の国際化に伴い、無錫冠雅はチャンスをつかんだ。中国国内で急速に発展しているだけでなく、積極的に海外市場を開拓し、低温度帯の発展における重要な企業の一つとなっている。
詳細を見る -
半導体恒温装置の価格をどう選ぶか?
1167現在、ほとんどの工業生産は、専門的な冷凍を提供する半導体恒温システムを必要としていると言える。効率的な半導体恒温システムは、さまざまな産業で大きな助けとなる。
詳細を見る -
蒸留装置用循環式冷凍機の使用上の注意点
1120再循環式冷凍機は補助蒸留装置であり、複数回気化濃縮して異なる混合物を分離する。蒸留装置と一緒に使用することで、蒸留装置の運転効率を向上させることができます。
詳細を見る