Tips for shutting down the industrial chiller for temperature control of the reactor
Industrial chillers are equipped with a wide range of accessories and equipment. In actual use, it is necessary to provide regular rest time for industrial chillers. In order to maintain stable performance during long-term operation, users need to master the actual use needs. The method of shutting down the industrial chiller to reduce problems such as excessive wear and tear of the equipment.

Method for shutting down the industrial chiller of the reactor temperature control unit:
1. When the chiller for industrial reactor needs to be shut down, it is necessary to first consider the shutdown range of the chiller before all shutdown operations can be performed. In order to avoid generating a large pressure, the user needs to close the suction shut-off valve to stop the operation of the compressor.
2. After closing the chiller compressor, it is necessary to operate the oil pump. Return the slide valve of the industrial single-reactor chiller to the 0-scale position, so that the load reduction reaches zero, and the oil pump will immediately stop all operations.
3. The chiller is used for a single industrial reactor, and the operation of the water pump and the cooling water tower needs to be stopped in the latter step. After such equipment is stopped, the entire power supply of the industrial single reactor freezer can be turned off, and the entire shutdown process of the industrial ice water machine can be completed. Ensure that the industrial chiller for a single reactor is in a shutdown state.
注意事項
1. If the machine is shut down for a long time, it is necessary to carry out special treatment for the industrial single reactor chiller. Including the condenser and the evaporator, it is necessary to completely pump the refrigerant to the condenser, and at the same time discharge all the water sources to avoid problems such as corrosion.
2. After the shutdown is completed, it is necessary to carry out detailed inspections for various accessories. The shutdown process is more particular, and the use of the shutdown steps can prolong the service life of the equipment.
要約する:
For the chiller for industrial single reactor that has been shut down for a long time, it is necessary to carry out careful testing to ensure that the equipment is kept away from various corrosive substances, and to improve the shutdown performance of the chiller for industrial single reactor.
関連推奨品
-
Disadvantages and advantages of general heat transfer oil heating circulation system
1073熱伝導オイル加熱サーキュレータは、直接加熱medium.Its利点に熱エネルギーに作用するように完全に閉じたループ構造を採用しています:(1)熱伝達表面の連続的な更新のために、熱損失は小さいです; (2...
詳細を見る -
なぜ半導体製造工程で使用される特殊ガスにチラーが必要なのか?
869When using special gases in semiconductor manufacturing processes, a chiller is required, mainly due to the following reasons: 3. Process requirements: In semiconductor manufacturing processes such as chemical vapor deposition...
詳細を見る -
-
新エネルギー自動車用バッテリーの電力試験システムとは?
943LNEYAパワーバッテリーシステムは、新エネルギー車のバッテリーテスト用にテストされているが、現代の新エネルギー車には多くの種類のバッテリーがある。では、どのような特徴があるのだろうか。三元リチウム電池とは、リチウム電池の...
詳細を見る