Left and right multi-layer test chamber
-80℃~150℃- Heating rate of preheating zone(No load) 5 ℃/min (customizable for 10-25 ℃)
- Cooling rate of pre cooling zone (No load) 2 ℃/min (customizable for 5-25 ℃)
- Pre cooling area Pre cooling range-10℃~-55℃
- Preheating area preheating range+60℃~+180℃
- 温度変動≤1℃
コンフィギュレーション詳細
モデル | GD-518-2-C-DC | |
Inner box size (W*H*D)cm |
Left cavity (cm) | 60*69*147.5 |
Right cavity (cm) | 60*69*147.5 | |
温度範囲 | -70℃~150℃ | |
Heating rate | (No load) -40℃→+125℃ 1℃/min (5~25℃ can be customized) | |
冷却率 | (No load) 125℃→-40℃ 1℃/min (5~25℃ can be customized) | |
Temperature uniformity | ≤±1℃ (no load) | |
温度精度 | ≤±0.1℃ | |
冷媒 | R404A/R23 | |
ヒーター | Electric heating | |
空冷コンデンサー | Fin heat exchanger | |
水冷コンデンサー | Plate/jacket/shell and tube heat exchanger | |
Air circulation | Extended shaft motor, stainless steel centrifugal fan blades | |
冷却方法 | Cascade refrigeration | |
コンプレッサー | Brand inverter compressor | |
Control method | Segmented fuzzy PID algorithm control | |
Communication protocol interface | TCP/RS485 (CAN can be customized) | |
操作パネル | 7インチカラータッチスクリーン、温度カーブ表示、EXCELデータエクスポート | |
Sensor | PT100A grade platinum resistor | |
Protective devices | Heater dual temperature protection, refrigeration system protection and electrical overcurrent and overload protection, etc. | |
Outer box size (W*H*D)cm |
357*238*175 | |
電源 | 380V 50HZ | |
Insulation material | Glass fiber wool & polyurethane | |
Inner box material | SUS304 stainless steel | |
Outer box material | Cold rolled steel plate + plastic spraying | |
Execution meets standards | GB/T 2423.1;GB/T 2423.2;GB/T 2423.3;GB/T 2423.4;GB/T 5170.2;GB/T 5170.5;GB/T 11158;GB/T 10589;GB/T 10592; GB/T 10586;IEC 60068-3-5 |
これらの製品にもご興味があるかもしれません。
ウォークイン試験室
APPLICATIONS Suitable for low temperature, high temperature, high and low temperature changes, constant damp heat, high and low temperature alternating damp heat and other tests of complete machines or large components. The size and fun…
2ドア衝撃試験室
APPLICATIONS When conducting high and low temperature shock tests, the test basket is mobile, mainly relying on the test basket to move up and down in the high temperature zone and the low temperature zone to complete the high and low t…
左右マルチレイヤー・テスト・チャンバー
APPLICATIONS Left and right multi-layer test chambers provide temperature range -80℃~+150℃ wide temperature range temperature control, no-load temperature uniformity ±1℃, temperature accuracy ±0.1℃, to meet the needs of diverse scenario…
GD Series Rapid Temperature Change Test Chamber
APPLICATIONS It is suitable for environmental stress screening tests. By performing environmental stress screening on products, it accelerates the discovery of product design defects and improves product reliability. Many industrial fie…
ロード...
已经是到最后一篇内容了!」。