高温・低温サイクル機の冷媒選択について
In the operation of high and low temperature cycle machines, the presence of refrigerant is essential, and the environmentally friendly mixed refrigerant used by LNEYA is better in terms of performance.
The high and low temperature cycle machine has a higher critical temperature and can undergo a phase change at normal temperature or normal low temperature, which is a basic requirement for the refrigerant in the steam high and low temperature cycle machine. High and low temperature cycle refrigerant suitable for saturated vapor pressure. Do not lower the evaporation pressure below atmospheric pressure to prevent air from leaking into the refrigeration system. The condensing pressure should not be too high to avoid excessive increase of high and low temperature cycle machines and equipment. At the same time, the ratio of the condensing pressure to the evaporation pressure should not be too large, so that the gas temperature is too high at the end of the compression and the gas transmission coefficient of the compressor is lowered.

The refrigerant solidification temperature is low to prevent the refrigerant from solidifying at the evaporation temperature. The viscosity and density are small to reduce the flow resistance loss of the refrigeration system. The high-temperature cycle machine has a high thermal conductivity to increase the heat transfer coefficient of the heat exchanger and reduce the heat transfer area and metal material consumption.
The refrigerant adiabatic index is small, which can reduce the power consumption of the compression process. At the end of the compression, the gas temperature is not too high, and the liquid heat capacity is small. The loss of the throttling process can be reduced, and the thermal perfection of the cycle is as large as possible. It does not burn, does not explode, is non-toxic, does not corrode to metal, does not have chemical action with lubricating oil, does not decompose under high temperature and is harmless to human body.
There are many types of refrigerants for high and low temperature cycle machines. The refrigerants used by different manufacturers are different. It is recommended that users choose environmentally friendly refrigerants better, energy saving and environmental protection.
関連推奨品
-
半導体冷暖房サーモスタットのコンプレッサー故障検出手順
786半導体冷暖房用サーモスタットにおいて、コンプレッサーは中核部品の一つである。ひとたび故障すれば、システム全体の動作に影響を及ぼす。故障を解決する方法は?半導体冷暖房用サーモスタットの不具合は、コンプレッサーが故障した場合に発生する。
詳細を見る -
100L高低温サーモスタット取付説明書
841100L高低温サーモスタットは、クーラントを伝達媒体として、冷却が必要な他の機器や装置から発生する熱を伝達し、その熱を冷凍機を通して機器の外部に放熱する。
詳細を見る -
小型水冷チラーの工業生産への影響とは?
1152小型水冷チラーは、食品加工業界や医薬品加工業界など、幅広い用途で使用されている。産業分野によっては、小型水冷式チラーが必要とされることも多い。小型水冷チラーの用途
詳細を見る -
化学反応釜の冷凍加熱温度制御システム
919反応釜冷却加熱温度制御システムは、反応釜の各種材料の温度制御に一定の役割を果たし、その温度制御効果は反応実験の結果に影響を与える。安定したオ...
詳細を見る