高温および低温冷凍循環ポンプの基本メンテナンス
Properly perform the sequence of opening and closing of the high and low temperature refrigeration cycle pump group to ensure normal operation after the host is started. Note that the condenser heats up well, otherwise the high temperature protection device of the high and low temperature refrigeration cycle pump group will stop and even cause malfunction due to the condensing temperature and the corresponding condensing pressure being too high. The cold water in the evaporator should be circulated, otherwise the cold water temperature will be low, the cold water temperature protection device will stop, or the low temperature protection device will stop due to the evaporation temperature and the corresponding evaporation pressure being too low, even leading to the evaporator. Cold water freezes and damages equipment.

Therefore, the boot sequence is: (must be strictly observed) Cooling tower fan on → cooling water pump on → cold water pump on → high and low temperature refrigeration cycle pump group. The shutdown sequence of the high and low temperature refrigeration circulating pump set is: (must be strictly observed) The equipment group stops → the cooling tower fan stops → the cooling water pump stops → the cold water pump stops. When the machine is shut down, the equipment group should be shut down half an hour before leaving work. The cold water pump is shut down after work, which is conducive to saving energy, avoiding downtime and protecting the unit. Before running the high and low temperature refrigeration cycle pump refrigeration cycle, make sure that the heating cycle pipe valves are all closed.
Maintenance of high and low temperature refrigeration circulating pumps is indispensable. At the same time, the operator needs to have certain operational knowledge of the equipment and will not find operational faults.
関連推奨品
-
We are LNEYA-a manufacturer of chillers
953There are many manufacturers of industrialchillers in the world, especially JULABO, huber, etc. that are known in theindustry. How much do you know about the production technology of industrialchillers? Now, in many industrial productions, indu...
詳細を見る -
直接接触式液冷とコールドプレート式液冷技術の違い
1234コールドプレート液冷技術は、加熱部品の熱を、コールドプレートを介して、循環パイプラインに封入された冷却液に間接的に伝達し、その熱を冷却する実施方法である。
詳細を見る -
高温・低温サイクル機の冷媒選択について
1117In the operation of high and low temperature cycle machines, the presence of refrigerant is essential, and the environmentally friendly mixed refrigerant used by LNEYA is better in terms of performance. The high and low temperature cycle machine h...
詳細を見る -
極低温冷却サーキュレーターの温度は?
1018LNEYA極低温冷却サーキュレーターは、-125度から-20度の冷却温度範囲を持っています。コンピューターカスケード温度コントローラーとPT100温度センサーを採用し、温度制御精度は±0.1度に達する。
詳細を見る