市販の一般的なガラス反応容器は、負圧ガラス反応容器、真空ガラス反応容器、高温高圧攪拌ガラス反応容器の3種類に分けられる。ガラス...
The glass reaction kettle mainly utilizes its double-layer glass characteristics. We can place reaction materials in the middle interlayer and stir the reaction under normal pressure or negative pressure. The glass reaction kettle injects a constant temperature hot solution or cooling liquid through the double-layer reaction kettle interlayer to heat or cool the materials inside the reactor at a constant temperature, and can provide stirring. In this way, the medium inside the interlayer of the glass reactor is stirred to perform a cyclic reaction, achieving heating or cooling effects. It is a commonly used biochemical instrument widely used in modern fine chemical, biopharmaceutical, scientific research and experimental industries. It can perform concentration, distillation, reflux, separation, and purification reactions under constant speed, force, and temperature conditions. It is an ideal instrument and equipment for teaching, experimentation, pilot testing, and production.
The double-layer glass reactor can provide high-temperature reaction (the maximum temperature can reach 300 ℃); The double-layer glass reactor can also perform low-temperature reactions (the minimum temperature can reach -80 ℃); A double-layer glass reactor can be evacuated to perform vacuum depressurization reactions. Its unique design makes the temperature control of the experiment more precise, ensuring that the experiment is conducted in a safer environment.
During experiments and production processes involving high or low temperature reactions, glass reaction vessels typically require a circulating chiller and heater to achieve precise temperature control.
The following situations explain why these two devices are needed:
Wide Temperature Range: When the reactor needs to operate over a wide temperature range, requiring both high-temperature reactions (such as up to 250 ℃ or above) and low-temperature reactions (as low as -80 ℃ or lower), it must be equipped with both a heater and a circulating chiller. A heater is used to heat the reaction medium, while a chiller is used for cooling to achieve the required reaction conditions.
High Temperature Control Accuracy: In experiments that require high temperature control accuracy, such as drug synthesis, fine chemical production, etc., the combination of circulating chillers and heaters can provide more accurate temperature regulation. Through closed-loop control systems, such as PID control, the temperature inside the reactor is maintained to have minimal fluctuations near the set value.
Continuous production or complex reaction processes: In complex reaction processes that require continuous production or involve multiple temperature stages, rapid response and precise adjustment of heating and cooling equipment have become particularly important. The integrated use of chillers and heaters can quickly adjust the temperature of the reaction vessel to meet the process requirements of different stages.
熱管理: A large amount of heat may be generated during the reaction process, and the chiller needs to remove excess heat in a timely manner to prevent overheating. At the same time, the heater can provide necessary heat supplementation in the early stage or low-temperature reaction stage.
Improving efficiency and product quality: Accurate temperature control can optimize reaction rate, improve product yield and purity. The combination of chiller and heater can significantly improve experimental or production efficiency and product quality.
RECIRCULATING CHILLERS
ロード...
已经是到最后一篇内容了!」。
CHILLERS & HEATERS
SUNDI Z 周波数変換シリーズ
WHATSAPP WECHAT 超高温冷却技術は、300℃の高温から直接冷却することができます[なぜなら膨張の熱媒体のみ...
スンディ -10℃~150
完全に封じられたシステム、単一の媒体は冷凍および暖房 -120~350℃ ±0.5℃ AC 380V 50HZ 8kW 最高を完了します 超高温冷却の技術は高温から直接冷却できます。
スンディ -80℃~250
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
SUNDI-320/320W
完全に封じられたシステム、単一の媒体は冷凍および暖房 -120~350℃±0.5℃を完了します 超高温冷却の技術は 300℃高温から直接冷却できます。超...
スンディ -25℃〜200
完全に密閉されたシステム、単一の媒体は冷凍および暖房を完了する -120~350℃ ±0.5℃ ● -120°Cから+350°Cまで働く温度 ●以前達成できなかった性能 ●理性的な温度調整...
スンディ -45℃〜250
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
スンディ -60℃~250
超高温冷却技術は、300℃の高温から直接冷却することができる[膨張室内の熱媒体のみが酸化物と接触するため]。
スンディ -80℃~250
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
スンディ -90℃~250
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
スンディ -100℃~100
動作温度範囲:-120°C~+350°C ●これまでにない性能 ●インテリジェントな温度制御 ●プロセスの安定性と再現性を最大化 ●アドッププレート式熱交換器、パイプライン加熱、高速...
ロード...
已经是到最后一篇内容了!」。
RECIRCULATING HEATERS
USTシリーズ
用途より多くの使用シーンでの温度制御に適していますリアクター、反応器、マイクロチャンネル、蒸留システムなどで使用され、他の機器の加熱や冷却にも使用されます。製薬、化学、バイオテクノロジーなど幅広い分野で使用されています。
UC/LYシリーズ加熱サーキュレータ
用途 製品の特徴 製品パラメータ 用途 蒸留および濃縮用温度制御ソリューション バ...
ロード...
已经是到最后一篇内容了!」。
We provide stand alone Rotary Evaporators,Glass Reactors , choose your equipment, and choose your set up. Call or email us for more details.
関連推奨品
-
Application of jacketed reactor cooling and heating circulator in chemical reactions
1029jacketed reactor cooling and heating system application
詳細を見る -
WTD-デュアル温度ゾーン
1687これは、マイクロチャンネル反応器の循環システムにおいて、液体保持容量が小さく、熱交換容量が大きく、圧力損失が大きいという特性に合わせて特別に設計・開発されたものである。
詳細を見る -
-