ハイブリッドカー・バッテリー試験装置冷却能力説明
Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehicle battery test equipment, once the outer surface of the insulation layer is found to have wet or frosted parts, it means that the thickness of the insulation material is insufficient or has been damp, and the insulation material should be added or replaced in time.
When the equipment is installed, a layer of insulation cotton is placed on the evaporator and the pipeline to prevent loss of cooling capacity. If the hybrid vehicle battery test equipment is slow in cooling, first check whether the thickness of the pipe insulation layer is not enough, or if the insulation layer is damaged, be sure to pack the insulation cotton and ensure that the thickness is sufficient!
Check for air in the equipment cooling system. When installing the hybrid vehicle battery test equipment, whether it is inside the unit, water pump, or pipeline, there can be no air, even if there is only a little air, the cold hybrid vehicle battery test equipment can not operate normally. In addition, there is a film inside the pump, and you must remember to tear it off before installation. Otherwise, the circulating water has no way to circulate or the circulation is very slow, which directly affects the operation of the hybrid vehicle battery test equipment.
Check the moving parts of the refrigeration compressor of the hybrid vehicle battery test equipment for wear, or increase the clearance, resulting in a decrease in the volume of gas. The compressor is the heart of the cooling water machine. If there is a problem with the compressor, the hybrid vehicle battery test equipment will not work. Therefore, the periodic inspection and maintenance of the compressor cannot be ignored.

The poor efficiency of equipment refrigeration compressors is also one of the reasons. In the long-term operation of the hybrid vehicle battery test equipment, the wear of the moving parts, the increase of the matching clearance or the tight sealing will reduce the actual air volume of the compressor and reduce the cooling capacity. Check the refrigeration compressor. If the repair is not good, it should be replaced in time. Air in the system can also cause this to happen. At this time, the exhaust pressure and temperature increase, the power consumption increases, and the cooling capacity decreases.
The cooling of the hybrid vehicle battery test equipment is related to the data of the hybrid vehicle battery test process, so the cooling capacity needs to be better according to the requirements.
関連推奨品
-
エチレングリコールチラーの主な目的は、反応器の加熱・冷却ユニットである。
1186グリコールチラーは、高純度金属、希少物質の精製、実験室環境でのシミュレーション、マグネトロンスパッタリング、真空コーティングなどの産業に適しています。大型クライオジェニックポンプユニットにより、労働環境の冷却が可能です。
詳細を見る -
Vocs 凝縮分離装置膨張弁メンテナンス説明書
922一旦、凝縮分離装置の膨張弁が故障すると、その解決策が間に合わなければ、凝縮分離装置全体が使用できなくなる可能性がある。そのため、凝縮分離装置の膨張弁の故障は、凝縮分離装置全体が使用できなくなる可能性がある。
詳細を見る -
Parts Analysis of Low Temperature Chiller
1152The low temperature chiller is a cooling water equipment which is widely used. So, when using it, you should first understand the principle of the cryogenic water chiller and its accessories, so as to run the cryogenic water chiller more efficient...
詳細を見る -
Performance Test of Household Refrigerator Designed by Environmental Chamber Sales
1305Many performance items of household refrigerators are tested under a specific environmental condition. The thermal condition of the air distribution in the environmental chamber is more severe than that in the general artificial constant temperatu...
詳細を見る