During the operation of the glycol chiller, it is critical that the refrigeration system does not leak.

In order to avoid the leakage of refrigerant and other gases from the glycol chiller, the inspection of the welding quality is more important. First check whether the sealing performance of the weld is good. After adding refrigerant or nitrogen and allowing it to stabilize for a certain period of time, it can be tested with soapy water or other methods. When the refrigeration cycle is in operation, the welds should not be cracked due to vibration, the pipes should not be blocked by debris during welding, and should not enter moisture due to improper operation. When the refrigeration cycle is working, the surface of the welded parts should be clean and clean. No oil stains.
The common leakage points of glycol chillers are evaporator leakage, refrigeration cycle connection leakage, refrigeration cycle valve leakage, compressor pipeline leakage, capillary vibration wear, four-way reversing valve leakage, etc. Common inspections Leakage methods are commonly used in the production and maintenance of refrigeration cycles: visual leak detection, pressure leak detection, instrument leak detection, vacuum leak detection, etc. The user can solve the leakage points one by one.
The fault of leak detection of glycol chiller is relatively common. Therefore, when choosing, it is recommended to choose a fully closed loop piping system and valve parts to choose branded accessories. The evaporator uses a high-power plate heat exchanger, which is small in size, high in efficiency, fast in cooling, safe and reliable, and is used for rapid liquid cooling. It is widely used in petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical, military and other high-tech industries.
関連推奨品
-
How to solve the fault of the ultra-low temperature refrigerator pressure controller?
1259If the industrial ultra-low temperature refrigerator encounters a controller-related failure during operation, if it is not resolved in time, the pressure controller may be unavailable. The pressure controller plays a very important role in the ul...
詳細を見る -
真空ポンプ温度制御システムの使用における誤解
912真空ポンプの温度制御システムを使用する場合、正しい操作方法のみが装置の正常で安定した動作を保証することができます。もし間違った操作方法が多ければ、装置の正常な使用に直接影響します。
詳細を見る -
Where are the applications of the CO2 supercritical extraction cryogenic refrigeration unit?
1033With the continuous development of co2 supercritical extraction technology, co2 supercritical extraction cryogenic refrigeration devices have attracted the attention of many industries due to their own characteristics, and have been widely used in...
詳細を見る -
原子炉温度制御システムのコンプレッサーキー保護
1258原子炉温度制御システムの運転において、コンプレッサーは中核部分であり、その性能はより重要である。そのため、コンプレッサーを保護する必要がある。通常の運転条件下では、原子炉温度制御システムのコンプレッサーは...
詳細を見る