高温と低温の閉ループ循環機を設置する際に注意すべき点は?
There are certain differences in the size and performance of high and low temperature fully enclosed circulators from different manufacturers. Users need to pay attention to the placement position when placing them after purchase. If the placement position is not good, it is not conducive to the operation of high and low temperature fully enclosed circulators.
In the installation of high and low temperature fully enclosed circulators, the heat dissipation efficiency of the high and low temperature closed loop circulators should be considered and the maintenance should be easy. The floor of the equipment must be flat and have sufficient strength (3.4 N/m2 or higher). Select a dust. And locations where vibration effects are small.
High and low temperature fully enclosed circulators are to be installed in a dry room with a high and low temperature fully enclosed circulator, and where there is a power supply and sewer nearby, the equipment should be installed in a place with little dust. The wind condition causes no oxygen deficiency to occur even if the refrigerant (fluorohydrocarbon) leaks from the equipment.
Good ventilation should be maintained around the installation of high and low temperature fully enclosed circulators. During operation, the device will radiate heat. If it is air-cooled, it will directly discharge heat through the condensed air. In the case of small room and poor ventilation, the indoor temperature will rise rapidly, causing the machine to stop running and alarm. . Installation of high and low temperature fully enclosed circulators should be kept away from flammable or explosive materials or other substances that may generate high heat.

When placing it, be careful not to let the sun directly project onto the device. When the device is used beyond this range, the safety device will start or the device will stop running. In order to achieve stable performance of the high and low temperature closed loop circulator, the installation room of the high and low temperature closed loop circulator should be air-conditioned to maintain the indoor temperature between 10 ° C and 30 ° C.
The atmospheric environment of the high and low temperature fully enclosed circulator installation site is consistent with the general indoor air-conditioned atmospheric environment. If organic solvents, plasticizers, acids, alkalis or other chemicals are present in the air, the parts or coatings of the equipment may be corroded and destroyed.
The precautions for placing the high and low temperature fully enclosed circulators should be taken seriously by our operators. Read the instruction manual in detail.
関連推奨品
-
Precautions for cooling and heating during operation of various reactors
915In many laboratories, various reaction vessels of chemical companies are indispensable reaction vessels, and its operating temperature: -80°C-250°C. The laboratory reactor works at normal temperature, and cooling water must be passed normally to a...
詳細を見る -
半導体冷凍温度制御テーブルクーラー操作説明書
1173半導体冷凍温度制御ステーションの変圧器冷却システムの制御システムの電源切替は、輸入された二重電源自動切替装置を使用しています。その主な機能は、電源の自動切り替えです。
詳細を見る -
-45℃冷凍庫メーカーがコンプレッサーの焼損検出と修理方法を分析
95145℃の冷凍庫では、コンプレッサーはより重要なコンポーネントの一つであり、製造元の無錫官也(LNEYA)は、コンプレッサーが故障したら、タイムリーな点検とメンテナンスが必要であることを皆に伝えている。
詳細を見る -
Temperature control unit necessary for Chinese medicine chemical raw material extraction-TCU
1205The production process of traditional Chinese medicine raw materials is relatively complicated: long process, many pipelines, and complicated operations; and most of the preparation raw materials are unstable, such as high environmental parameters...
詳細を見る