Knowledge Sharing Of Chiller Selection And Maintenance
Chillers can be used in a lot of industry, but who is the better low temperature chiller manufacturer in トップ冷凍機メーカー?Let me tell you. The choice of own model and the maintenance are also very important. Next, see with me.
1. Range of temperature control
According to different temperature ranges, chillers are divided into standard chillers and low temperature chillers. The temperature range of the standard chiller is 3-35 degrees, and the temperature range of the low temperature chiller is 0-20 degrees.
2. Type selection
Industrial water chillers are mainly divided into water-cooled chillers and air-cooled chillers. Water cooled chillers need to be equipped with cooling towers, circulating pumps, and water towers are used for heat dissipation. The air-cooled chiller does not need any other equipment. It carries out heat exchange through its own fans and air.
3. Model selection
After determining the type of chiller, it is also necessary to choose the model. Because there are many specifications and models for each chiller. So when we install the chillers, we must carefully calculate the parameters such as refrigerating capacity and freezing water volume.
The methods of chiller maintenance ?
1.コンプレッサー
Compressor is a key component in the unit. The quality of the compressor is directly related to the stability of the unit.
2. the cleaning of the condenser and evaporator
Because the cooling water of the water cooled condenser is an open loop circuit, the tap water commonly used is circulate through the cooling tower. When the content of calcium salt and magnesium salt in the water is large, it is easy to decompose and deposit on the cooling water pipe to form grime and affect heat transfer.
関連推奨品
-
超低温コンプレッサーユニットにおけるフィルターの作用の説明
1101超低温コンプレッサーユニットの運転を安定させるためには、コンプレッサーの性能が非常に重要であり、コンプレッサーに加えてフィルターも重要である。正常な運転を維持するためには、コンプレッサーに加え、フィルターも重要である。
詳細を見る -
Multi-stage refrigeration system centrifugal compressor repair instructions
1362After the centrifugal compressor of the cascade refrigeration system is disassembled, the dimensions of each journal (cooperating with the impeller, bearing, coupling, etc.) are measured with an outer diameter micrometer to calculate the roundness...
詳細を見る -
密閉式冷凍加熱サーキュレーター日常のメンテナンスマニュアル
1355異なるメーカーの密閉式冷凍・加熱サーキュレーターには一定の寿命があります。密閉式冷凍・加熱サーキュレーターの合理的で正しい操作とメンテナンスは、効果的に耐用年数を延ばすことができます。ユーザー...
詳細を見る -
新エネルギーモーター試験水冷システムの故障率を下げるには?
1000新エネルギーモーター試験水冷システムは、使用中の使用に注意を払う必要があり、どんなに良い設備を長期間使用しても、多かれ少なかれ何らかの問題が発生する。では、どうすれば使用中の設備の故障率を最小化できるのか。
詳細を見る