屋内用冷凍機と屋外用冷凍機の主な違い
屋内用チラーと屋外用チラーは、どちらも特定の冷却ニーズに合わせて冷水を供給するための装置だが、設計、設置場所、使用環境、放熱方法などに大きな違いがある。
The following are the main differences between indoor chillers and outdoor chillers:
Installation location:
Indoor chiller: As the name suggests, installed inside buildings such as computer rooms, equipment rooms, laboratories, data centers, etc., located in the same indoor environment as the cooled equipment or system.
Outdoor chiller: installed outside buildings, such as roofs, terraces, dedicated equipment platforms, or floors, separated from the cooled equipment, usually in an open or semi open outdoor environment.
Working environment:
Indoor chiller: The working environment is relatively stable, less affected by external climate changes, and factors such as temperature, humidity, and dust are relatively controllable. But it is necessary to consider the ventilation, noise control, and coordinated layout with other equipment in the indoor space.
Outdoor chiller: Directly exposed to outdoor climate conditions, the working environment changes greatly, and needs to cope with various weather conditions (such as high temperature, low temperature, wind and rain, sand and dust, etc.), and may face greater corrosion risks. Design should consider measures such as rain protection, sun protection, dust prevention, frost resistance, and anti heat island effect.
Heat dissipation method:
Indoor chiller: Heat dissipation is usually achieved through air-cooled or water-cooled condensers. The air-cooled indoor chiller uses a built-in fan to directly discharge the heat generated by the condenser into the indoor air, which is then discharged through the indoor ventilation system. The water-cooled indoor chiller is connected to a cooling tower or cooling water system to transfer heat to the outside through the circulation of cooling water.
Outdoor chiller: It often uses air-cooled condensers to use outdoor air for natural or forced convection heat dissipation. Outdoor chillers are usually equipped with large air flow fans and large-area heat dissipation fins to enhance heat dissipation efficiency. In cold regions, antifreeze devices such as electric heaters or hot gas bypass valves may also be required.
Noise control:
Indoor chiller: Due to its installation indoors, there are high requirements for noise control, and noise reduction measures are usually designed, such as soundproof covers, silencers, low-noise fans, etc., to reduce the impact on the working environment.
Outdoor chiller: Although installed outdoors and relatively less sensitive to noise, it still needs to comply with certain environmental standards and community regulations. Some high-end outdoor chillers adopt appropriate noise reduction designs, but overall, their noise control requirements are slightly lower compared to indoor chillers.
Maintenance convenience:
Indoor chiller: Due to its relatively concentrated location, it is easy for daily inspection and maintenance. But it may be necessary to consider the entry and exit channels of indoor space, equipment relocation, and coordination with other facilities.
Outdoor chiller: During maintenance, it may be necessary to consider safe climbing, harsh weather conditions, and compatibility with the building’s exterior. However, due to its distance from the work area, the impact of maintenance operations on normal operations is relatively small.
Installation costs and limitations:
Indoor chillers: Factors such as indoor space occupation, ventilation facility renovation, and increased air conditioning load may need to be considered, especially in places with limited space or special environmental requirements (such as clean rooms), where installation costs and complexity may be high.
Outdoor chiller: It is necessary to consider outdoor installation conditions such as building structural load-bearing, waterproofing, lightning protection, drainage, power supply, insulation, as well as possible regulatory limitations such as urban planning, environmental protection, and noise control.
In summary, there are significant differences between indoor and outdoor chillers in terms of installation location, working environment, heat dissipation method, noise control, maintenance convenience, installation cost and limitations. The selection of which type should be based on factors such as actual application environment, building conditions, cooling requirements, cost budget, and local regulations.
LTZインバータ Mシリーズ
用途 目的の温度制御対象物への適用に適しており、すでに低温貯蔵タンクと循環ポンプがあり、媒体はLTZ Mシリーズ冷凍温度制御ユニットに輸送されます。
LN -60°C~-10°C
适用范围 製品特徴 製品参數 製品パラメータ 行业应用 応用 航空航天材料|试验装置控温解决方案 在航空航天领域,材料的性能直接关系到飞行器的安全,可靠性和...
LT -80℃~-20
それは水混合物と混合されるエチレン・グリコールの循環の冷凍 24 時間の連続操作を保証できます 1.資源を救う循環の冷凍のために水と混合されるエチレン・グリコールを使用できます 2.Cir...
温冷両回路温度制御ユニット
* ,
LTZ可変周波数Mシリーズ
すでに保冷タンクと循環ポンプを持つ温度制御対象物に適しています。媒体は循環ポンプを通してLTZ Mシリーズ冷凍ユニットに輸送されます。
LTGスクリュー冷凍機ユニット
それは化学薬品、薬剤、機械類および他の分野のさまざまな生産プロセスの冷たい源のために適して、氷の貯蔵、低温の空気供給および他として使用することができる -110℃~30℃冷凍媒体を提供できます。
ZLTZ 効率的な熱交換器シリーズ
ZLTZ温度制御ユニットは、マイクロチャンネルリアクターと組み合わされ、高放熱温度制御アプリケーションを形成する。
LT-800 ミニ・チラー
LNEYAミニチラーは、ロータリーエバポレーター用の実験室で使用される小型の冷水機です。
LJ -45°C~ -10°C
速い冷却および低い冷却の温度 -5~-150°C 水冷 LNEYA は単一液体低温学のスリラーの生産を専門にします。冷凍温度は-150°Cから-5°Cまでであり、...
LD -80°C~ -30°C
5℃〜-150℃の1.Temperature範囲は、異なる温度2を満たすことができます。有名なブランドの半閉鎖したピストン圧縮機、半閉鎖した両極ピストン圧縮機、半密閉ねじ圧縮機、主要なブランドは BOCK です。Bitzer、Cop...
LT -45℃~30
速い液体冷却のための低温冷却の循環器 1.資源を節約する循環の冷凍のために水と混合されるエチレン・グリコールを使用できます 2.Circulating パイプラインの設計は、t.を延長します。
LT -60℃~-20
水と混合したエチレングリコールの循環冷凍 媒体が抽出タンクに入った後、それは閉じなければならず、サンドイッチが加熱され、冷媒は、抽出タンクの熱源を低減するためにオンにします。
ロード...
已经是到最后一篇内容了!」。
関連推奨品
-
10馬力フリーザー・パイプ清掃手順書
100810馬力冷凍機はLNEYA社の工業用低温処理装置です。冷凍機を使用して冷却する過程で、パイプラインの洗浄が不十分だと冷凍機を使用してしまうので、パイプラインの洗浄が必要です。ヘ...
詳細を見る -
低温チラーシステムにおける電子膨張弁の使用について
1155低温チラーシステムにおいて、電子膨張弁は、コンプレッサー、コンデンサー、エバポレーター、水冷式スクリュー冷凍機、空冷式スクリュー冷凍機...と協力して、システムの運転動力を制御する上で重要な役割を果たす。
詳細を見る -
LNEYA’s 300,000 kcal air-cooled unit on air tightness
1114When the user runs the 300,000 kcal air-cooling unit, it needs to check the air tightness, because the airtightness may cause the air-cooling unit to consume too much energy. In order to prevent the temperature from falling for a long time during ...
詳細を見る -
空気によって冷却されるスリラー装置の詳しい紹介
1269LNEYA冷凍は10年以上の冷却サポートアプリケーションの経験を蓄積してきました。さまざまな応用分野とサービス条件に応じて、空冷式冷凍機を含むさまざまなタイプの冷却冷凍機を開発しました。
詳細を見る