10馬力フリーザー・パイプ清掃手順書
10馬力冷凍機はLNEYA社の工業用低温処理装置です。冷凍機を使用して冷却する過程で、パイプラインの洗浄が不十分だと冷凍機を使用してしまうので、パイプラインの洗浄が必要です。ヘ...
Remove the heat transfer medium before cleaning the 10hp freezer. Connect a suitable drain to the drain and allow it to flow into a suitable container (make sure the tube and container match the heat transfer media). Open the drain valve, the heat transfer medium flows from the external application to the pump chamber and then flows from the drain port to the container at low temperature to remove the heat transfer medium. Be sure to take protective measures to prevent low temperature frostbite. Open the freezer filling port and carefully purge the heat transfer medium in the system by carefully blowing nitrogen into the heat transfer medium outlet (pressure below 3BAR).
Replace 10hp freezer heat transfer oil / internal cleaning, please be careful not to use acetone as a cleaning solvent. Failure to do so will destroy the tightness of the 10hp freezer. After discharging according to the previous section, depending on the heat transfer medium, a lot of residue of the heat transfer medium remains in the pump chamber and the inner container. Fill in a suitable solvent, such as a silicone oil cycle to clean the internal components, including the pump chamber, internal vessels, conduits, etc. Depending on the situation of the contamination, it may be necessary to repeat this method several times. Then let the instrument open all the drain valves and connections. Please note that before using the new heat-conducting medium to control the temperature in ultra-low temperature operation, please be sure to remove the moisture in the system. Otherwise, the viscosity of the heat-conducting medium will increase when the temperature is low, and the heat transfer capacity will be reduced.
When cleaning the 10hp freezer pipe, be careful that the heat transfer medium must be cleaned, otherwise the media will cause the freezer to malfunction.

関連推奨品
-
-
How to solve the common faults of industrial circulating chillers?
1045For industrial circulating chillers, if they are always in a high-temperature operating state, a large amount of cold air will be seriously lost. After ensuring the sealing effect of the use environment, effective thermal insulation can be carried...
詳細を見る -
Workflow and Equipment Composition of Oil Refining and Dewaxing
1027The oil dewaxing process is based on the melting point difference between the wax and the oil and the solubility of the wax in the oil becomes smaller as the temperature decreases, and the crystalline wax is precipitated by cooling. Then through t...
詳細を見る -
機械部品の低温加工用冷凍機の使用と液体窒素との比較
952In the machinery manufacturing industry, the quality requirements for parts are very strict. In order to better improve the performance of machinery, improve product quality and life, a new technology-cryogenic treatment has been produced. During ...
詳細を見る