Cooling system of liquid-cooled energy storage cabinet-chiller
With the development of new energy technology, the application of containerized energy storage systems in new energy, photovoltaic, and electric energy stations has increased. If the temperature of the energy storage battery pack is not well controlled, the temperature of the battery will be unstable, leading to an increased risk of short circuit and damage to surrounding components.
The containerized energy storage system is mainly composed of a containerized machine room, a battery management system, and a battery pack temperature control system. Therefore, the cooling system of the special containerized energy storage system is becoming more and more high-performance and highly stable. The temperature control system includes chillers, chiller pipes, air conditioners, and air ducts. Provide suitable and stable ambient temperature for the overall container energy storage system.
During the work of the containerized energy storage system, the lithium battery system, battery management system, energy storage monitoring and other systems will generate a lot of heat due to current changes. In order to ensure the efficient operation of the energy storage system at all times, some systems will be equipped with dedicated energy storage system cooling units , The cooling method is divided into two types: air-cooled and water-cooled.
LNEYA’s energy storage integrated cabinet cooling system follows a compact design and can be an external cooling system for the battery pack energy storage integrated cabinet. Efficient nanny-style thermal management system is suitable for applications where the battery inside the energy storage container generates a lot of heat and is sensitive to ambient temperature. Integrate upper computer communication, alarm and other functions, without complicated debugging.
Liquid cooling is integrated into each battery cabinet using glycol antifreeze. The system is fully enclosed design, supports dual system cooling circuits, mutual backup to avoid battery shutdown and safety failure; intelligent, multi-language color touch screen, provides clear and comprehensive important data information, and can display flow pressure data in real time; liquid cooling system IP50 The above protection can meet the anti-corrosion requirements, and can be used below 3000 meters above sea level. The temperature setting range is -45°C~55°C, and the liquid temperature can be precisely controlled within ±0.5°C.


関連推奨品
-
液冷チラー(業務用蓄電池)
2355バッテリーエネルギー貯蔵システムは、多くのバッテリーセルで満たされており、大量の極端な熱負荷を発生させます。これは、冷却システムが温度を正確に制御し、効率的に熱を放散する必要があることを意味します。
詳細を見る -
液冷チラー(チャージングパイル)
2283Model CHDYL-4 -45℃~55℃ Cooling Power 4KW Temp control accuracy ±1℃ Real-time temperature record Refrigerant Brine circulation system fully enclosed design Flow 1.8~5.5L/min Pressure 0.7bar Minimum water inlet temperature 15°C ...
詳細を見る -
液体冷却チラー(エネルギー貯蔵)
3222モデル CNYL -45~55 冷却容量 45KW 温度調整の正確さ ±0.5℃実時間温度の記録 二次冷却剤 エチレン・グリコール不凍剤、冷却する循環系の十分に封じられた設計 冷媒 R41...
詳細を見る -
高温・低温サイクル機の冷媒選択について
1117In the operation of high and low temperature cycle machines, the presence of refrigerant is essential, and the environmentally friendly mixed refrigerant used by LNEYA is better in terms of performance. The high and low temperature cycle machine h...
詳細を見る -
無錫官哉、冷凍水チラーの冷凍条件を判断する方法を分析する
870冷却された水スリラーを購入するとき、スリラーの質を知りたいと思えばスリラーの冷凍状態を見ることができる。よいスリラーの冷凍効果は長期ope...で比較的安定し、有効である。
詳細を見る -
ルネア冷凍のサーモスタットバスSC
1432Lneya冷凍会社の恒温槽は、広く化学試薬、医薬品、生物学的製品の乾燥、蒸留、濃縮、浸漬に使用され、恒温槽加熱や他の温度にも使用することができます...
詳細を見る -
Aerospace equipment parts cryogenic test freezer refrigeration troubleshooting instructions
1259Cooling water inlet temperature is too low Ultra-low temperature freezer for ultra-low temperature testing of aerospace equipment components As the temperature of the cooling water decreases, the compressor discharge pressure, exhaust temperature,...
詳細を見る