Manufacturers now use recycled water to save costs. However, many manufacturers put circulating water of the whole plant in one water network, which will lead to the problems that the temperature of circulating water cannot be controlled well, the water quality is poor and the backwater pressure is difficult to solve. After communicating with many manufacturers, we know it is very expensive to transform the circulating water network. Therefore, we need to pay attention to some matters when we use water cooling device. In accordance with the actual situation of the user, we have summarized some cautions to share with you:
1. The water cooler must be cleaned and tested regularly.
2. Increase the current oil viscosity of the equipment by 1-2 brands: in general, customers use VSG68, which is recommended to be changed to VSG100 or even VSG150 to improve the safety margin of system oil temperature.
3. During the winter, the ambient temperature may be below 0 degrees. Pay attention to the water discharge in the water cooler, so as not to damage the water cooler.
4. Ensure the cooling water flow reaches the technical requirements, and the water inlet needs to follow the water filter.
5. The backwater pressure needs to be reduced as much as possible.
1. The water cooler must be cleaned and tested regularly.
2. Increase the current oil viscosity of the equipment by 1-2 brands: in general, customers use VSG68, which is recommended to be changed to VSG100 or even VSG150 to improve the safety margin of system oil temperature.
3. During the winter, the ambient temperature may be below 0 degrees. Pay attention to the water discharge in the water cooler, so as not to damage the water cooler.
4. Ensure the cooling water flow reaches the technical requirements, and the water inlet needs to follow the water filter.
5. The backwater pressure needs to be reduced as much as possible.
前の記事 工業用冷凍機の用途次だ: 塩水噴霧環境チャンバーの一般的な不具合
関連推奨品
-
高温・低温循環タンク冷凍プロセスの説明
1377高温・低温循環タンクを使用する過程で、不適切な使用による些細な問題が発生する可能性があり、無錫官也高温・低温循環タンクの冷凍工程に問題が発生する可能性があり、その後、...
詳細を見る -
ステンレス鋼製極低温冷凍機の高圧破損
1271ステンレス製極低温冷凍機コンプレッサーの高速回転により、温度が上昇し、コンプレッサーが高気圧を発生させ、高電圧保護リレーが作動する。コンプレッサーの吐出圧力が上昇し、コンプレッサーの吐出圧力が低下します。
詳細を見る -
自動車産業におけるテストベンチのための動的で正確な温度シミュレーション
915品質と安全性のテストは、自動車産業の開発と生産プロセス全体の中核をなす要素です。KRY-475および455プロセス冷却サーキュレータにより、私たちはお客様に完璧な温度制御ソリューションを提供します。
詳細を見る -
ICテストにおける温度の重要性
1512すべての集積回路(IC)は、それが販売され、製品を構築するために使用される前に、2つのタイプのテストを通過します:1つ目は、ウェハテストと呼ばれ、2つ目は、最終テストと呼ばれています。ウェハー・テストと呼ばれるものと、ファイナル・テストと呼ばれるものである。
詳細を見る