新エネルギー自動車用パワーバッテリー試験システムにおける共通故障の分析
If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the body all connections (positive and negative lead, sampling line interface) .
Close the maintenance switch assembly, multimeter test battery pack parameters: closed maintenance switch, use a multimeter to measure the total voltage of the power battery V, use a multimeter to measure the positive and body voltage V1, use a multimeter to measure the negative and body voltage V2, multimeter pen replacement Parallel fixed value resistance meter pen, and set the gear position to the resistance file, measure the fixed value resistance value R, multimeter table position back to the DC voltage file, measure the parallel resistance, the positive pole and the body voltage V1, measure the parallel resistance, the negative pole and the body After the voltage V2 is measured, disconnect the maintenance switch.

If a new energy vehicle battery encounters a temperature-type fault, it means that the vehicle does not have an OK file. The instrument panel indicates that the power battery temperature is too high. After a temperature alarm occurs, the manager, the wiring harness, and the like need to be excluded (replacement manager, The manager and the battery pack are connected to the sampling harness); if the fault persists after the replacement, it is judged that the power battery is faulty.
Wuxi Guanya New Energy Battery Cooling Test System Platform reminds that if the power battery is seriously unbalanced, check the vehicle for full charge and charge, and switch BMS test 80%, 50%, 0% single-cell battery voltage data flow, observe and compare If the low battery voltage is the same, the fault still replaces the power battery.
If there are other faults in the battery pack in the automotive power battery test system, it is recommended to contact the battery manufacturer for processing.
関連推奨品
-
LNEYA:温度制御TCUに注力し、国際的な先進中国機器を構築
1061広い温度範囲:LNEYAの中国と生産グレードのマルチ原子炉冷凍加熱温度制御システム(温度制御ユニットTCU)-25℃〜200℃の温度範囲は、もちろん、あなたはまた、他の温度をカスタマイズすることができます。
詳細を見る -
耐圧防爆高温および低温1機械メーカーの指示インストールポイント
1184防爆高低温一体型機械が工場から納入された後、目的地に到着してから設置しなければなりません。設置の際に注意すべき点は?防爆高低温一体型機械は、防爆仕様を備えています。
詳細を見る -
エバポレーター付きトランスミッション・パワートレイン冷却システム
977蒸発器は、冷凍システムの4つの主要コンポーネントの1つであり、冷凍効果と効率の究極の具体化である。蒸発器は一般的に、トランスミッションのパワートレイン冷却システムによって設計され、装備されています。
詳細を見る -
実験室における循環水チラーの選択の要点について語る。
950循環水冷却器はチラーとも呼ばれる。それは一定した温度、一定した流れおよび一定した圧力を提供できる冷却水装置の一種である。現在、市場には多くの種類のチラーがある。どのように適切なチラーを購入する...
詳細を見る