エバポレーター付きトランスミッション・パワートレイン冷却システム
The evaporator is one of the four major components of the refrigeration system, and it is the ultimate embodiment of the refrigeration effect and efficiency. The evaporator is generally designed and equipped by the transmission powertrain cooling system manufacturer, and the user does not need to choose. However, in order to better maintain the refrigeration system and ensure its operation, the following points should be noted:
1. The influence of liquid level on evaporation temperature. Due to the height of the refrigerant liquid column, the evaporation temperature at the bottom of the flooded evaporator is higher than the evaporation temperature of the liquid surface. The evaporation temperature of different refrigerants at different liquid levels is affected differently by the height of the static liquid. Regardless of the refrigerant, the lower the evaporation temperature of the liquid surface, the greater the influence of the hydrostatic height on the evaporation temperature. Therefore, only when the evaporation pressure is high, the influence of the hydrostatic height on the evaporation temperature can be ignored. When the evaporation temperature is low, it cannot be ignored. In other words, it becomes uneconomical to use a flooded evaporator at this time.
2. The possibility of freezing of the refrigerant. If the evaporation temperature is lower than the freezing temperature of the refrigerant, the refrigerant may freeze. When water is used as the refrigerant, theoretically, the temperature of the inner wall of the tube can be as low as possible. However, for the sake of simplicity, the temperature of the inner wall of the pipe at the outlet end of the latter process is usually kept above. For the case of brine as the refrigerant, according to the same principle, the temperature of the inner wall of the tube should be higher than the freezing temperature of the refrigerant.
3. The pressure loss of the refrigerant in the evaporator. When the refrigerant flows through the evaporator, pressure loss is caused, which will inevitably make the pressure p2 of the refrigerant at the outlet of the evaporator be lower than the pressure p1 at the inlet, thereby reducing the suction pressure of the compressor, resulting in a decline in the refrigeration capacity.
4. According to different models, the choice of evaporator is different. For example, the cooling system of the box-type small transmission powertrain uses a water tank coil type evaporator; the open type small transmission powertrain cooling system and the small screw type For transmission powertrain cooling system, shell and tube evaporator is used; for acid and alkali resistant transmission powertrain cooling system, titanium tube evaporator or stainless steel plate exchanger can be selected.
There are many options for the cooling system of the small transmission powertrain. Of course, it can be customized according to the needs of users.
関連推奨品
-
半導体チップ高温・低温テスターのコストを下げるには?
1052電子製品の急速な発展に伴い、製品の品質が向上する一方で、製品価格の下落が消費者に評価されるようになっている。電子製品の価格を引き下げるためには、まず、電子製品の品質を向上させる必要がある。
詳細を見る -
How to use a multimeter to test the components of the chip test temperature control machine?
1015The chip test temperature controller is used for IC, CPU, GPU, DPU, BGA, FCBGA, LGA, QFN, QFP, CSP, WLCSP, Bare Die, and other Device Under Test. So, how to use a multimeter for these commonly used components What about testing? For electronic com...
詳細を見る -
工業用高温・低温冷却システムの作動特性
988工業用高温低温冷却システムは、主に温度、圧力、流量、液面、湿度、pH値などの監視と制御に使用されます。高い制御精度、高い信頼性、高い信頼性、高い信頼性、高い信頼性、高い信頼性、高い信頼性、高い信頼性、高い信頼性。
詳細を見る -
バッテリーパック冷却水装置 チラー使用上の注意事項
960バッテリーパック冷却循環水機チラーは、新エネルギーバッテリーパックの冷却システムに使用されます。電池パック冷却循環水機チラーは、新エネルギー電池パック冷却システムに使用され、使用者は操作中に誤用を避けるために注意を払う必要があります。
詳細を見る