LNEYA temperature control system AH series commentary
Refrigeration heating temperature control system AH series, suitable for high heat release, suitable for SUS reactor, temperature difference > 150 ° C, can quickly cool high temperature reaction, polymerization reaction and rapid heating and cooling temperature.
With the progress of society, industrial development is also developing rapidly. Therefore, refrigeration circulators have attracted the attention of many companies.
Nowadays, many chemical plants and laboratory research institutes have great demand for this, and they can be heated and cooled. Its maximum temperature range can reach: – 25 ~ 200 degrees, to ensure immediate cooling under high temperature conditions, can achieve continuous temperature control of 200 ~ 25 degrees.
Compared to other companies, our refrigeration circulators have a wide operating temperature range because our refrigeration equipment is a closed system. It does not absorb moisture at low temperatures. It does not produce oil mist at high temperatures. The heat transfer oil can be adapted to a wide operating temperature range. The solenoid valve is not used throughout the circulatory system. The circulation management is completely sealed, without oil mist and water absorption, ensuring the safety and thermal life of the experiment. It also has a variety of security features.

関連推奨品
-
Integrated circuit temperature control device research description
981At present, integrated circuit temperature control is used in the integrated circuit, semiconductor, and chip industries. Then, for the testing needs of such industries, integrated circuit temperature control is necessary. At present, there are se...
詳細を見る -
Configuration form of circulating heating unit for laboratory
934The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
詳細を見る -
How To Vacuum The Ultra-Low Temperature Freezer Refrigeration System?
1051LNEYA ultra-low temperature freezer indoor and outdoor connection has been completed, observe the oil pump oil mark indication to see if there is enough oil, and then start the vacuum pump to see if it is normal. Then unscrew the large valve back ...
詳細を見る -
なぜ電気会社は冷却システム産業用冷凍機を必要とするのか?
929電気機器が屋外で使用される場合、高温環境に遭遇することがある。例えば、夏の直射日光の下では、温度が非常に高くなることがあります。機器が過熱すると、性能に影響が出たり、あるいは故障につながったりすることがあります。
詳細を見る