Instructions for the LNEYA 5hp Freezer Condenser
5hp freezer is one of the most demanding equipments in the industrial cold processing industry. Wuxi Guanya (LNEYA) is one of the related manufacturers, reminding users that when choosing a 5hp freezer condenser, we need to pay attention to the use and maintenance. The matter is clearly understood.
With the operation of the 5hp freezer evaporative condenser, part of the water evaporates, minerals and other impurities in the water are left behind to accumulate in the pool of the evaporative condenser. Therefore, the refrigerant must be inspected regularly and cleaned regularly. Good control of water quality and prevention of scaling. The fresh water should be cleaned with fresh water, and it must be filtered when there is impurities in the water. If the supplemental water is too hard, softened water treatment should also be considered. The water treatment plan should be developed in conjunction with an experienced professional water treatment company.
Always check the operation of the evaporative cold water pump and the fan, and do regular maintenance and inspection. Whether the two components operate normally will directly affect the heat transfer effect. The 5hp freezer evaporative condenser should also consider the antifreeze of circulating water during winter operation, especially in northern China.
Systems using a 5 hp freezer evaporative condenser should note that the presence of non-condensable gases in the system will significantly reduce the heat transfer of the evaporator, resulting in higher condensing pressure. Therefore, the air venting operation must be performed frequently, especially the low temperature system in which the chiller suction pressure is a negative pressure. In actual use of the evaporative condenser, the use state of the evaporative condenser and the number of units used should be adjusted according to the changes in the environment and the area of use in different seasons, so that the system can operate economically and achieve energy saving.
When the 5hp freezer system heat load is relatively small, or the temperature is relatively low, the number of evaporative condensers can be reduced. When the ambient temperature is relatively low, the fan operation is stopped, and only the water pump can be turned on, and the refrigerant is condensed by water alone. When the temperature drops below the freezing point, pay attention to the antifreeze problem of the water, and ensure that the water does not freeze.
Maintenance is important for the use of its equipment, so regular maintenance of the various components of the 5hp freezer is necessary.

関連推奨品
-
化学企業向け循環水冷凍機設備の試運転
1026After completing the installation of circulating water chillers in chemical enterprises, certain debugging needs to be carried out for industrial chemical circulating water chillers in the early stage of operation. Only through careful debug...
詳細を見る -
What are the refrigerants for the 120-degree ultra-low temperature freezer?
1337The refrigerants of different ultra-low temperature freezer manufacturers are different. The refrigerants commonly used in LNEYA refrigeration equipment are R404, R22, etc. So, what is the difference between the two-120-degree ultra-low temperatur...
詳細を見る -
半導体温度制御装置用コントローラーの機能とは?
775In the temperature control equipment of semiconductor components, each accessory has a different function. Due to the different functions, the function of the temperature control valve and controller of the semiconductor components of LNEYA is dif...
詳細を見る -
真空ヒートシンクチラーの特徴と用途
705真空ヒートシンク・チラーは、高真空環境で冷却を行うために特別に設計された装置の一種で、科学研究、半導体製造、航空宇宙など、高真空を必要とする分野で一般的に使用されている。
詳細を見る