The relationship between vocs adsorption condensing equipment price and configuration
The quality of vocs adsorption condensing equipment must be guaranteed. This can be used with confidence. The reason for the power consumption may also be that the gas inhaled by the BITZER compressor allows a certain degree of superheat, but the superheat is too large. The specific volume increases, the cooling capacity decreases, and the relative power consumption increases. The Bucher compressor comes to the frost, quickly closes the small suction valve, sharply reduces the amount of cooling, and relatively increases the power consumption.
As the evaporation temperature of the vocs adsorption condensing equipment decreases, the compression ratio of the BITZER compressor increases, and the energy consumption per unit of cooling capacity increases. When the evaporation temperature is lowered by 1 ° C, it consumes 3% to 4% more. Therefore, the evaporation temperature difference is reduced as much as possible, and the evaporation temperature is increased, which not only saves power consumption, but also improves the relative humidity of the cold room.
During the cooling process, the condensing temperature increases, the compression ratio of the compressor increases, and the energy consumption per unit of cooling capacity increases. If the heat exchange surface of the condenser and the evaporator is covered with an oil layer, the condensation temperature rises and the evaporation temperature decreases, resulting in a decrease in the amount of cooling and an increase in power consumption.
When the scale of the wall of the condenser of the condensing device of the condensing device reaches 1.5 mm, the condensation temperature rises by 2.8 ° C than the temperature before the fouling, and the power consumption increases by 9.7. The vocs adsorption condensing device evaporator surface is covered with a layer of frost, which reduces the heat transfer coefficient. Especially when the outer surface of the finned tube is frosted, it not only increases the heat transfer resistance but also makes the air flow between the fins difficult. Reduce the heat transfer coefficient and heat dissipation area of the exterior. When the indoor temperature is lower than 0 °C, when the temperature difference between the two sides of the evaporator tube group is 10 °C, the heat transfer coefficient of the evaporator after working for one month is about 70 before frosting.
The price of vocs adsorption condensing equipment is still appropriate depending on the configuration. Wuxi Guanya (LNEYA) has been carefully developed and achieved satisfactory results.

関連推奨品
-
High temperature fault treatment of temperature shock test equipment
1046The whole function of Wuxi Guanya LNEYA thermal shock test chamber is computer controlled. It is a self-developed software with a good operation interface, which makes the operation and monitoring of the user simpler and more intuitive. The mainte...
詳細を見る -
The Application of Industrial Chillers
950The chiller machine is needed in a lot of industries, basically chemical, medical, pharmaceutical industries are involved, then what industry can Wuxi Lneya chiller meet in the end? It is known that we are one of the top chiller manufacturers. Th...
詳細を見る -
原子炉温度制御システムのコンプレッサーキー保護
1262原子炉温度制御システムの運転において、コンプレッサーは中核部分であり、その性能はより重要である。そのため、コンプレッサーを保護する必要がある。通常の運転条件下では、原子炉温度制御システムのコンプレッサーは...
詳細を見る -
How to prevent the freezing pressure of the bearing quick freezing box from being too low?
1160In the refrigeration system of the bearing blast chiller, if the condenser installation is not in the enclosed space, the system's exhaust pressure (condensation pressure) tends to be lower in winter (or low temperature), which is often more commo...
詳細を見る