超低温における結露温度と凝縮温度の関係
The chilling temperature of the 超低温循環式冷凍機 refers to the temperature at which the state of the substance changes from a gaseous state to a liquid state under a certain pressure. Different substances have different condensation temperatures. For the same substance, changes in external pressure can also cause changes in the condensing temperature. The condensation temperature of the pure substance is a temperature point, and for the mixture, the boiling range elongation condensation is a temperature range. In general, as the outside air pressure increases, the condensing temperature also rises, and vice versa. In short, it is a function of matter, composition and pressure.
The level of condensation temperature depends mainly on the temperature and flow rate of the cooling medium, the condensation area and the form of the condenser. Reducing the condensing temperature can increase the refrigeration capacity of the compressor and reduce the power consumption, thereby increasing the refrigeration coefficient and improving the economics of operation. However, the condensing temperature should not be too low, otherwise it will affect the circulation of the refrigerant, and the cooling capacity will decrease. If the condensing temperature is too high, not only the cooling capacity will decrease, but also the power consumption will increase, and the exhaust temperature of the compressor will increase, the temperature of the lubricating oil will increase, and the viscosity will decrease.
There is also a certain correspondence between the condensation temperature of the ultra low temperature recirculating chiller and the condensing pressure. Therefore, the adjustment of the condensing temperature can also be achieved by adjusting the condensing pressure. When the temperature of the cooling medium (water or air) is constant, the adjustment of the condensing pressure can be achieved by changing the flow rate and the condensation area of the cooling medium. The flow rate of the cooling medium is increased, and the flow rate is correspondingly increased, the heat transfer temperature difference can be reduced, thereby reducing the condensation temperature; and increasing the heat transfer area can also achieve the purpose of reducing the condensation pressure.
関連推奨品
-
空冷冷水機構化学反応冷凍装置のトラブルシューティング方法
1132もし化学反応釜の空冷冷水機構冷凍ユニット系統に空気が入ると、その影響は多い。まず空気循環系統に入って、圧力が上昇して、凝縮器の放熱効果は......
詳細を見る -
特殊環境用コンポーネント・テスター
1625With the continuous development of the semiconductor industry, component component testing has been widely used in components in the fields of industry, scientific research, pharmaceuticals, and chemical industry. At present, there are quite a few...
詳細を見る -
超低温チラーの選択とメンテナンス
905今日、あるお客様が実験用の小型冷水機の必要性について問い合わせに来られた。具体的な作業条件は、20Lのステンレス製リアクター内の材料を常温からマイナス30℃まで1時間以上かけて下げること。このプ...
詳細を見る -
超低温冷蔵庫のシェル&チューブ・コンデンサーのスケールを除去するには?
1126Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...