超低温循環式冷凍機用膨張弁の選び方
Selection and installation of the expansion valve for 超低温循環式冷凍機: the selection of expansion valve plays an important role in the performance of the ultra low temperature recirculating chiller refrigeration system. The correct choice of expansion valve will maximize the use of the evaporator and make the evaporator always be matched to the heat load.
First, the selection of thermal expansion valve.
In the ultra low temperature recirculating chiller refrigeration system, the selection and installation of the expansion valve is very important. Only the correct selection and installation can ensure the normal operation of the unit. Therefore, when selecting the expansion valve, we can use the appropriate size of the thermal expansion valve according to the size of the evaporator load and the evaporating temperature. The capacity of the commonly used expansion valve is about 20% larger than the evaporator heat load. For small chiller refrigeration systems, gas-filled thermal expansion valves are generally used, and medium-sized ultra-low temperature circulating chiller refrigeration systems mostly use adsorption-filled or mixed-filled expansion valves.
Second, the expansion valve installation.
1. The chiller expansion valve is installed in front of the evaporator and is usually installed in a vertical position. Considering the ease of installation and maintenance, the cooling loss is small and should be as close as possible to the inlet of the evaporator.
2. The working condition of the expansion valve for the ultra low temperature recirculating chiller has a direct relationship with the installation position of the temperature sensing package. Because the expansion valve completely adjusts the opening size of the expansion valve by the temperature change of the temperature sensing package. The temperature sensor package is installed on the pipe at the outlet of the chiller evaporator. As the evaporator outlet pipe grows, its superheat gradually increases. Therefore, the position of the expansion valve temperature sensing package is directly related to the amount of fluid supplied from the expansion valve.
関連推奨品
-
Product Features of Fluid Heat Transfer Temperature Control System
1028The fluid heat transfer temperature control system is the refrigeration and heating device of the matching reactor reactor in the pharmaceutical chemical industry. So, what are the characteristics of the fluid heat transfer temperature control sys...
詳細を見る -
About 60p Refrigerated chiller energy consumption is too large
1344The performance of 60p Refrigerated chiller of different manufacturers is different, and the energy consumption is also different. If the energy consumption of 60p Refrigerated chiller is too large, it is necessary to check in time to see if ther...
詳細を見る -
真空チャンバー冷却チラー
955真空チャンバー冷却チラーは、真空チャンバー内の環境を冷却するために特別に設計された装置で、真空チャンバー内の温度が特定のアプリケーションのニーズを満たすために必要な動作範囲内に保たれるようにします。
詳細を見る -
小規模蒸留精製用温度制御循環装置の作動状態
933蒸留還流濃縮精製温度制御循環装置は、多くの分野で広く使用されています。適切な装置を選択することは非常に重要であり、製品の品質を大幅に向上させ、生産コストを削減することができます。
詳細を見る