The Refrigeration Principle of Heating Cooling Circulator
Heating cooling circulator is the use of limited refrigerant in the closed refrigeration system, repeatedly refrigerant compression, condensation, expansion, evaporation, constantly in the evaporator heat absorption vaporization, cooling.
について heating cooling circulator is the circulation process that moves the heat from the low temperature object (such as the cold storage) to the high temperature object through the refrigerant, so as to cool the object below the ambient temperature and maintain the low temperature. This process is realized by the refrigeration device
The important parameter of the heating and cooling circulator is the coefficient of refrigeration, also known as the performance coefficient of the refrigeration unit, represented by the symbol COP. At a given ambient temperature, the lower the temperature of the cold storage, the smaller the coefficient of refrigeration.
The whole liquid cycle is closed, with the expansion vessel, the expansion vessel and the liquid cycle are insulated, do not participate in the liquid cycle, just mechanically connected, temperature the medium in the expansion vessel is less than 60 degrees no matter the liquid cycle temperature is high or low.
The whole liquid circulation is a closed system. At low temperature, there is no water vapor absorption, and at high temperature, there is no oil mist generation. Thermal oil has a wide range of operating temperature. No mechanical or electronic valves are used throughout the system.
Analysis of refrigeration principle
01.Compressed air refrigeration cycle
Due to the air constant temperature heating and constant temperature exhaust heat is not easy to achieve, so it can not run by the reverse cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of the reverse cycle, so it can be regarded as the reverse cycle. In engineering applications, the compressor may be either piston or impeller type.
02.Compressed vapor refrigeration cycle
The reverse refrigeration cycle of compressed steam can be achieved in theory, but it will appear that the dry state is too low, which is not a positive factor for two-phase material compression. In order to avoid adverse factors, increase the refrigeration efficiency and simplify the equipment, in practical applications often use throttle valve (or expansion valve) to replace the expander.
関連推奨品
-
冷暖房システムはどのようにして同時温度制御を実現しているのですか?
1027温度制御システム サーモスタットは暖房と冷房機能を持ち、-120℃~320℃の連続温度制御のために同じ媒体を使用することができます。冷暖房システムの冷暖房システムは、主に4つの部品で構成されています。
詳細を見る -
Treatment of insufficient exhaust gas in high and low temperature impact test chamber compressor
1194The efficiency of the high and low temperature impact test chamber during use is very important. If there is a shortage of high compressor exhaust, we need our LNEYA technicians to solve it in time. So, how to solve it better? The high and low tem...
詳細を見る -
高温・低温液体循環式冷凍機の氷詰まりに対応する小型クーラー
826高温および低温の液体循環式冷凍機の運転において、氷詰まりは比較的よく見られる故障です。関連メーカーの経験に基づき、氷詰まりに対処するためのヒントを特別にまとめました。配管内の...
詳細を見る -
40GW極低温冷凍機の機種選定と分類の説明
1146無錫官哉40GW極低温冷凍機は、企業や業種が違えば、機種選定も異なります。ですから、40GW極低温冷凍機の選択のニーズを明確に理解する方がよいでしょう。
詳細を見る