冷暖房システムはどのようにして同時温度制御を実現しているのですか?
Temperature control system The thermostat has heating and cooling functions, and can use the same medium for continuous temperature control from -120℃~320℃.
The heating and cooling system of cooling and heating system is mainly composed of four parts: heat exchanger, compressor, evaporator and condenser, and it is also one of the very key components of the whole high and low temperature integrated machine. The heat exchanger is mainly to transfer heat from the hot fluid to the cold fluid, the heat exchanger has a four-way valve, which can cool the heat exchanger. The condenser is part of the cooling system of the high and low temperature all-in-one machine, which converts gas or vapor into liquid, and can transfer the heat in the pipe to the nearby air. The evaporator is one of the very important components of refrigeration. The low-temperature condensate exchanges heat with the outside air through the evaporator, and evaporates to absorb heat. The evaporator is mainly composed of a heating chamber and an evaporation chamber. The heating chamber provides the heat needed to evaporate the liquid to promote boiling and evaporation of the liquid.

The cooling and heating system is suitable for equipment connected to reaction devices for refrigeration and heating reactions in the pharmaceutical and chemical industries. There are many production steps that require reliable temperature control as part of prototyping equipment. The working principle is to drive the heat transfer medium (usually water, ethanol, silicone oil, etc.) from the oil tank with built-in heater to the temperature control equipment through the pump, and then return to the oil tank from the temperature control equipment. The controller adjusts the temperature of the thermal fluid to adjust the temperature of the temperature control device according to the temperature of the thermal fluid measured by the temperature sensor or the internal temperature of the temperature control device. In recent years, there have been more and more applications in the chemical industry. After purchasing the high and low temperature cycle machine, it is necessary to carry out actual operation, but many users are not very familiar with its main operation. If the operation is not performed according to the requirements, it will not only affect the performance and life of the equipment, but may even be dangerous. Accidents happen.
関連推奨品
-
真空チャンバー冷凍加熱サーモスタット制御ユニットのエネルギーを節約する方法
1254省エネ・省排出運転の環境では、LNEYA真空チャンバー冷却・加熱サーモスタット制御ユニットをどのように操作するかが非常に重要です。消費電力を削減するためのヒントをいくつか見てみましょう。
詳細を見る -
LNEYA’s 300,000 kcal air-cooled unit on air tightness
1115When the user runs the 300,000 kcal air-cooling unit, it needs to check the air tightness, because the airtightness may cause the air-cooling unit to consume too much energy. In order to prevent the temperature from falling for a long time during ...
詳細を見る -
ガラスリアクターの選び方温度制御システムの合わせ方は?
967ガラス釜リアクターは多くの実験設備に必要であり、一般的に温度制御システムと共に使用される。化学と製薬の分野では、輸入ガラス反応釜は基本的に必需品であり、冷凍熱...
詳細を見る -