温水サーキュレーターの原理説明
について 温水サーキュレーター is mainly used to improve the following problems: when the gas water heater is too far away from the bathroom, causing the hot water to come out slowly in the shower, especially when the hot water bathing liquid is shut off in the middle of the shower, and the hot water is turned on after the bathing liquid, it will take a long time for the hot water to come out, which is extremely unbearable in the winter. However, the 温水サーキュレーター (hereinafter referred to as the backwater circulator) is by no means as magical as the merchants boast that it can instantly produce constant temperature hot water. Its working principle is to be explained to you by the simplest model.
The kitchen and bathroom of the hardcover room are located at both ends of the diagonal line of the house, and there is no return pipe in the gas water heater. After installing the water returner, the following changes occur: after opening the main and guard hot water, hot water is pushed into part of the cold water pipe by the driving of the return water motor and the guiding of the one-way valve installed under the farthest basin, besides flowing out of the hot water pipe, hot water is pushed into the cold water pipe through the one-way valve (which can also be understood as the function of the return water pipe). Before installing the one-way valve, the position is disconnected, and the cold water pipe and the hot water pipe are not connected. When the hot water is turned on again after shutting down the hot water, the hot water left in the cold water pipe of the part having black line indicating and the cold water in the total intake pipe enter the water heater together and are heated, because the cold water and hot water are neutralized, which makes the initial water temperature higher and alleviates the problem of the lag of the hot water after heating. But it’s not the instant constant temperature hot water, but the first warm water (the residual hot water in the original hot water pipeline), then a small hot water (the residual hot water in the original water heater), and then a cool water (the water heater reaction lags behind the unheated water, in fact, the front hot water is not heated, but was left in the pipe last time heated. At last, the water temperature backs to the normal temperature. Moreover, if the hot water shutdown time is too long, the original cold water pipe will also cool down, and the effect will be worse. Nevertheless, the device improves the bathing experience, and the time spent waiting for cold water to pass is much shorter.

前の記事 低温チラーの主な機能次だ: 高温環境チャンバーの設計とテスト技術 販売
関連推奨品
-
どのような電池パック試験室が実験室に適合しますか?
762実験室でのバッテリーパック試験室の使用は、試験結果の正確性と安全性を保証するために、一連の厳しい要件を満たす必要があります。これらの要件には主に以下の側面が含まれます:温度コン...
詳細を見る -
小規模蒸留精製用温度制御循環装置の作動状態
936蒸留還流濃縮精製温度制御循環装置は、多くの分野で広く使用されています。適切な装置を選択することは非常に重要であり、製品の品質を大幅に向上させ、生産コストを削減することができます。
詳細を見る -
低温冷凍機の運転で発生する騒音の原因分析
1021騒音は、産業機器の運転において一般的なものです。ノイズが発生する原因はさまざまで、設置場所の環境問題が原因となっている場合もあります。ノイズが発生した場合、まずその原因を確認し、それがインター...
詳細を見る -
Introduction of LNEYA Semiconductor Temperature Test System
1214The semiconductor temperature test system is an indispensable part of the semiconductor process. The LNEYA semiconductor temperature test system is dedicated to various semiconductor tests. The semiconductor temperature test system runs through th...
詳細を見る