Thermal oil heating system installation and fault analysis
When the heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil heating system device.
The faults of the heat transfer oil heating system device can be roughly divided into two categories: mechanical fault and system fault. Mechanical fault refers to the detachment and damage of the heating device, fuel blockage, circulation pump, valve leakage, etc. are collectively referred to as mechanical faults, and mechanical faults can pass through small and medium Overhaul to solve.
Heat transfer oil heating system device system failure needs to pay attention to whether the heat transfer oil heating system device is designed reasonably, install and use the standard heating system. After the heat transfer oil is operated for a period of time under high temperature conditions, a series of changes are inevitable. For example, the viscosity increases, the residual carbon increases, etc., which causes the system to have abnormal pressure and difficulty in heating. If it cannot be solved in time and effectively, the situation will deteriorate rapidly. The reason is that the heat transfer oil will be in the furnace after carbonization. The inner surface of the tube forms coking, and the formation of the coke layer will intensify the carbonization speed of the oil film. Such a vicious cycle will not only quickly scrap the oil, but also cause high temperature oxidation and peeling of the outer surface of the tube, and the tube wall becomes thinner and thinner. “.

In addition, a considerable part is an irregular heating system. In some systems, the heating furnace is self-made or modified; some systems lack the necessary accessories such as circulation pump and expansion tank, and some models and sizes are unreasonable. The problem of electric heating system is even more serious. The service life of heat transfer oil is short, and frequent system failure is a common problem. Therefore, it is very important to choose a regular heat conduction oil heating system device manufacturer.
The related faults of the heat transfer oil heating system device need to be solved in a timely and effective manner at the beginning of the occurrence, so as to avoid the improper disposal of the heat transfer oil heating system device.
(This article is from the source network. If there is any infringement, please contact LNEYA for deletion, thank you.)
関連推奨品
-
Why is the mode of cooling water circulator mainly water circulation?
911Cooling water circulator is a way to use water for cooling. With the increase in ambient temperature, many companies have also found that the use of circulating water is increasing. The supplement of circulating water is aimed at the water cooling...
詳細を見る -
Temperature control during new energy vehicle battery test
1142With the continuous implementation of energy saving and emission reduction policies, new energy power batteries are also continuously encouraged to develop, and liquid cooling systems have become an inevitable trend for new energy vehicles. The or...
詳細を見る -
超低温冷蔵庫のシェル&チューブ・コンデンサーのスケールを除去するには?
1121Low-temperature refrigerator ultra-low temperature condenser scale removal In general, we have three methods, namely mechanical descaling, chemical pickling and descaling, and electronic magnetic water separator descaling. Low-temperature refriger...
詳細を見る -
RF chip high and low temperature automatic test machine control system description
1323Based on the continuous development of the semiconductor chip industry, LNEYA RF chip high and low temperature automatic test machine is also promoted to consumers. So, what do you know about the RF chip high and low temperature automatic tester s...
詳細を見る