Principle analysis of operation of refrigeration heating circulator
With the continuous development of technology, more and more refrigeration equipment has appeared in our lives, such as: refrigeration and heating circulators, in fact, they are not ordinary, are remarkable refrigeration equipment.
The refrigeration heating circulator uses a limited amount of refrigerant in a closed refrigeration system to repeatedly compress, condense, expand, and evaporate the refrigerant, and continuously absorbs heat and vaporizes at the evaporator to perform cooling and cooling. The process of cooling the object to below ambient temperature and maintaining the low temperature by the refrigerant moving the heat from a low temperature object (such as a cold storage) to a high temperature object is achieved by using a refrigeration device.
An important parameter of the refrigeration heating circulator is the refrigeration coefficient, also known as the operating coefficient of the refrigeration unit, indicated by the symbol COP. The refrigeration heating circulator Xiaobian tells everyone that at a certain ambient temperature, the lower the cold storage temperature, the smaller the cooling coefficient.
So, what are its advantages?
The entire liquid circulation is hermetic, with an expansion vessel, the expansion vessel and the liquid circulation are adiabatic, do not participate in the liquid circulation, but are mechanically connected, regardless of whether the temperature of the liquid circulation is high temperature or the medium in the low temperature expansion vessel is less than 60 degrees. .
The entire liquid circulation is a closed system. There is no absorption of water vapor at low temperatures. There is no oil mist at high temperatures. The heat transfer oil can have a wide operating temperature; mechanical and electronic valves are not used in the entire circulation system.
Next, let’s look at the refrigeration principle of the refrigeration heating circulator.

Compressed air refrigeration cycle
Since the air temperature heating and the constant temperature heat removal are not easy to achieve, it cannot be operated in the reverse cycle. In the compressed air refrigeration cycle, two constant pressure processes are used to replace the two constant temperature processes of the reverse cycle, so it can be regarded as a reverse cycle. In engineering applications, the compressor can be piston or impeller.
Compressed vapor refrigeration cycle
The reverse refrigeration cycle of compressed steam can be theoretically achieved, but a state of too low dryness will occur, which is not conducive to the compression of two-phase materials. Refrigeration heating circulators, which tell you that in order to avoid adverse factors, increase cooling efficiency and simplify equipment, throttle valves (or expansion valves) are often used instead of expanders in practical applications.
The compressed vapor refrigeration cycle uses a low-boiling substance as a refrigerant, and utilizes the constant pressure in the wet vapor zone to determine the temperature, and the constant pressure gasification endothermic refrigeration at a low temperature can overcome some of the disadvantages of the above-mentioned compressed air and regenerative compressed air circulation.
Absorption refrigeration cycle
The absorption refrigeration cycle utilizes the different solubility characteristics of the refrigerant at different temperatures in the solution, so that the refrigerant is absorbed by the absorbent (ie solvent) at a lower temperature and pressure, while at the same time making it at a higher temperature and pressure. Evaporate from the solution and complete the cycle for refrigeration purposes.
関連推奨品
-
蒸留塔プロセスチラー加熱システム
1075蒸留塔と蒸留塔プロセスでは、プロセス中の温度制御を維持し、効果的な分離と精製操作を確実にするために、確かに冷却装置と加熱装置が必要です。蒸留塔の塔頂温度は...
詳細を見る -
LNEYA star refrigeration heating system SUNDI-320/420W/430W
1211Today, I will introduce the model of LNEYA's refrigeration heating system: SUNDI-320/420W/430W. It has three kinds of medium temperature range: -30°C~180°C; -40°C~180°C; -40°C~200°C. The control system is programmed to program up to 10 programs...
詳細を見る -
Which part of the chip testing system requires high and low temperature control?
805In the chip testing system, the environmental control equipment requires high and low temperature control. Specifically, this section mainly includes the following two key devices: 2. Temperature control system: For certain testing app...
詳細を見る -
循環式冷凍機の機器故障アラームの対処法
913循環式冷凍機の使用中に故障やアラームが発生した場合、どうすればいいのでしょうか?生産性を確保するためには、このような問題を迅速に解決する必要があります。私たちはまず、故障やアラームの原因を理解し、さまざまな対処法を採用する必要があります。
詳細を見る