ロータリーエバポレーター用低温クーラント循環ポンプ
The chemical and pharmaceutical fields are the largest end consumer markets for cryogenic coolant circulation pumps. With the increasing demand for low-temperature coolant circulation pumps in this market, the application of cryogenic pumps in the chemical industry is becoming more mature. As a laboratory instrument, cryogenic coolant circulation pumps are indispensable to the laboratory field. It plays an important role in chemical, pharmaceutical and chemical research.

The low-temperature coolant circulation pump can directly cool test tubes, reaction flasks, etc. to carry out chemical reactions at low temperatures, and carry out low-temperature storage of chemicals and biological products. It can also be used in conjunction with rotary evaporators, vacuum freeze-drying boxes, circulating water-type multi-purpose vacuum pumps, etc.
One low temperature coolant circulation pump with two rotary evaporation laboratory cases Note points:
When in use, the actual temperature should not be lower than the minimum temperature. If water is used as the circulating solution, the water inlet pipe cannot be higher than 60 degrees Celsius, but when using absolute ethanol, the water inlet can not be higher than 10 degrees Celsius.

Lneya low-temperature coolant circulation pump adopts international brand compressor, which has small volume and high efficiency. Single compressor can achieve -152°C temperature control. The shell material is cold-rolled steel plate, and the circulating pump with pressure ≤6bar can be customized to make the liquid storage larger capacity according to the needs. Exclusive self-cascade supercooling refrigeration technology, in order to save water resources, can use ethylene glycol-water mixture for circulating refrigeration, strict circulation pipeline design, prevent circulating water pollution, extend the circulating water use time; -125 ° C ~-20 °C Wide temperature range; adjustment unit 0.1 degree. Ambient temperature monitoring function is provided to prevent damage to the system when the ambient temperature is too high.
関連推奨品
-
バッテリーテストチラー運転蒸発温度の説明
1256現在の新エネルギー自動車バッテリー試験装置では、より多くのバッテリーを使用してチラー蒸発温度をテストすると、装置に一定の影響を与えるが、具体的な影響は何ですか?バッテリー試験用冷凍機の熱負荷が増加した場合...
詳細を見る -
大型冷凍機の消費電力の理由は?
953大型冷凍機の運転中、冷却能力と作業条件が電力消費の主な問題となるが、無駄な電力消費を避けるためには、明確に理解する必要がある。規模が大きくなると、消費電力は大きくなる。
詳細を見る -
有機廃ガス精製凝縮シャットダウンノート
1197有機性排ガスを精製・凝縮した場合、運転中に故障が発生すれば、その時点で運転を停止して廃棄しなければなりません。では、一度停止した有機廃ガス精製・濃縮装置はどのように使用できるのでしょうか。その...
詳細を見る -
石油暖房システムの設置および故障分析
1299熱媒油暖房システム装置を設置する際、設置中にいくつかの不具合が発生しないよう、システムに注意を払う必要がある。故障が発生した場合、熱転写油加熱システムに関連する故障を理解する必要があります。
詳細を見る