いつTCU温度制御システムを選択するか?
First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
関連推奨品
-
-
屋内用冷凍機と屋外用冷凍機の主な違い
877屋内用チラーと屋外用チラーは、どちらも特定の冷却ニーズに合わせて冷水を供給するための装置だが、設計、設置場所、使用環境、放熱方法などに大きな違いがある。
詳細を見る -
LNEYA 高温・低温加熱式冷蔵庫 メンテナンス手順書
1158循環水を使用する高温・低温加熱冷蔵庫は、循環水を1カ月ごとに定期的に交換する。熱媒油を使用している場合は、半年から1年ごとに熱媒油を定期的に交換する。高温・低温加熱式冷蔵庫の場合
詳細を見る -
原子炉水冷チラー停止時不使用時の注意事項
1102原子炉水冷式冷凍機は付属品が完備している場合、実際の使用において、定期的な休息時間を設ける必要がある。長期にわたって安定した性能を維持するためには、使用者がその方法をマスターする必要がある。
詳細を見る