空冷式および水冷式サーキュレーターの冷却および加熱方法
冷却加熱サーキュレーターは運転中、高温と低温で制御される。ユーザーが高温と低温で動作した後、それは水冷と空冷である熱伝達油で加熱することができます。1.それは...

1. It belongs to electronic equipment. It should be cleaned, dusted, and energized regularly to prevent the components from being damaged by moisture. Partial inspection and performance inspection should be carried out regularly to understand their technical status and ensure that the equipment is always in good working condition.
2. Maintenance should be carried out regularly such as cleaning, lubrication, rust prevention, dustproof, moisture-proof, anti-corrosion and other maintenance work.
3. The anti-sinking filter should be cleaned at least once every two weeks, and it should be regularly maintained and cleaned to improve the heat dissipation effect, and to prevent the need of overload-induced fire and damage to the equipment.
4. The heat transfer medium is in a closed system with an expansion vessel, and the heat transfer medium in the expansion vessel does not participate in the circulation.
5. In the process of temperature control, the material, quantity, size, inlet and outlet temperature, flow rate, temperature control accuracy, temperature control time and other working conditions of the reactor are required.
6. Understand the principle of temperature control, the temperature control methods of different manufacturers are different, and choose the equipment that suits you.
7. Understand and analyze the quality, performance, structure, configuration, accessories, price, after-sales service, distribution, etc. of the analysis equipment, choose the correct manufacturer, and avoid wasting money and time by choosing the wrong one.
These two cooling methods are selected according to the environment in which they are located. They are used in the industry that requires temperature control of the reactor. They mainly help customers to speed up the progress of the reactor experiment and meet the fixed cooling or heating temperature requirements. The air cooling of the all-in-one cooling and heating cycle test refers to the heat convection generated by the air flow, thereby reducing the temperature of the box to achieve cooling. Water cooling refers to cooling by flowing water or other coolant, and the cooling efficiency of water is generally higher than that of wind.
The two cooling methods for cooling a heating circulator are not straightforward. High and low temperature boxes according to the environment. Various types of manufacturers have certain differences. Users need to choose the actual situation according to their specific situation.
関連推奨品
-
完全密閉式冷凍・暖房機の運転特性の説明
1402石油、化学、製薬業界では、完全密閉式の冷凍・暖房一体型機械が多くの企業で必要とされている。しかし、ユーザーが選択する際には、その運転特性を理解する必要がある。
詳細を見る -
伝熱オイルヒーターだけでは不十分な場合はどうすればいいのですか?
1085熱転写オイル電気加熱装置は、高温・低温統合機、冷凍・加熱統合機、冷凍加熱動的温度制御システムとも呼ばれ、従来の電気加熱装置に代わるものである。
詳細を見る -
Motor test bench test and temperature system for vehicle components
1359All vehicle components must undergo rigorous testing, but safety programs must undergo more stringent durability and terminal testing. Many physical methods can be used to load the motor, but the small motor test bench is favored for its high spee...
詳細を見る -