バイオ医薬品研究室用オイルクーラーの安定した性能を維持するには?

1. A suitable working environment to prevent various failures of the oil cooler in the biopharmaceutical laboratory needs to provide a better operating environment for the equipment. Keep the environment clean and tidy, reduce the impact of various types of dust, thereby improving the stability of heat dissipation, improving the cooling performance, reducing the ambient temperature in a shorter period of time, and reducing the energy consumption of equipment used by enterprises.
2. Maintain a low failure rate, and carry out meticulous maintenance and maintenance on a daily basis. At the same time, operators are required to complete the opening and closing of the equipment according to the use steps required by the manufacturer, so as to avoid wrong operation behaviors and lead to the use of oil coolers in biopharmaceutical laboratories. Life is affected, and even various failures continue to occur.
3. Timely maintenance of minor faults requires the company to timely and effectively complete the entire maintenance process for the failure of the oil cooler in the biopharmaceutical laboratory to reduce the impact of minor faults.
4. It is strictly forbidden to short-circuit the water flow switch circuit during the use of the equipment. Short-circuiting may cause the equipment pipes to freeze and damage, which will affect the normal use of the equipment.
5. In actual operation, operators are required to record various operating data of the equipment on time, analyze regularly, find problems through data, and eliminate hidden dangers for problems.
6. When an alarm occurs, the meaning of the alarm should be judged in time. If it cannot be solved by itself, it should be reported to the refrigerator manufacturer for repair to avoid the expansion of the fault range and the overrun of the maintenance cost.
7. It is strictly forbidden to short-circuit the water flow switch circuit during the use of the equipment. Short-circuiting may cause the equipment pipes to freeze and damage, which will affect the normal use of the equipment.
8. In actual operation, operators are required to record various operating data of the equipment on time, analyze regularly, find problems through data, and eliminate hidden dangers for problems.
In addition to the above methods, the operation management of the oil cooler in the biopharmaceutical laboratory is also very critical. Mastering the scientific operation procedures, maintenance and repair methods of the equipment, as well as the management of the maintenance, transformation and disposal of the refrigeration unit can ensure that the equipment is always in good condition. operating status.
関連推奨品
-
Why is there air in the reactor temperature control system?
952The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the powe...
詳細を見る -
How to deal with chip failure in integrated circuit chip test?
1192The integrated circuit chip test is used in various chips, semiconductors, and component tests. Once the chip fails, the test work will stop. Therefore, the ineffective user of the integrated circuit chip test needs to know clearly. The purpose of...
詳細を見る -
無錫観亜:新エネルギー開発に貢献するため、冷凍暖房機器の研究開発に注力
13602018年10月17日、南京国際博覧センターで3日間のAPIが開催された。展示会は多くの人で賑わっていた。無錫冠雅はAPIによく来ていた。無錫観亜定温冷凍技術有限公司(Wuxi Guanya Constant Temperature Refrigeration Technology Co.(以下...
詳細を見る -
酸化拡散プロセスにおける温度制御と冷却装置
732酸化拡散プロセスは、半導体製造における重要なステップである。主に精密な酸化膜の形成とドーピングに使用され、温度制御には極めて厳しい条件が要求される。このプロセスでは、チラーが重要な...
詳細を見る