In the operation of the reactor temperature control system, the compressor is the core part, and its performance is more important. Therefore, it is necessary to protect the compressor.

Under normal working conditions, the compressor of the temperature control system of the reactor should inhale the dry vapor of the refrigerant. There is also lubricating oil entering the cylinder. If there is too much liquid entering, it is too late to discharge from the exhaust valve, and the pressure in the cylinder will rise sharply to form a liquid hammer, which is the damage to the cylinder, valve, piston, connecting rod and other parts. Therefore, various protective measures can be taken for the temperature control system of the reactor, such as installing a gas-liquid separator to separate the liquid entrained in the low-pressure steam to ensure the dry stroke of the compressor; installing an oil heater to lubricate the compressor before starting Oil is added to reduce the amount of refrigerant dissolved in the lubricating oil; or the air valve assembly is pressed against the end of the cylinder with a spring to form a false cover.
In order to ensure that the motor of the temperature control system of the reactor is not overheated, in addition to correct use and attention to maintenance, an overheat relay of the temperature control system of the reactor can also be installed; there is also phase loss protection. If the commonly used three-phase motor is out of phase, it will cause the temperature control of the reactor. If the system motor cannot be started or is overloaded, the overload relay of the reactor temperature control system can be used to avoid damage to the motor due to lack of phase.
The temperature protection method of the exhaust temperature of the reactor temperature control system is mainly to place the thermostat near the exhaust port of the reactor temperature control system. When the exhaust temperature is too high, the thermostat will act to cut off the circuit. If the shell temperature of the reactor temperature control system unit is too high, it will affect the life of the compressor, which is mainly caused by the insufficient heat exchange capacity of the condenser. Therefore, it is necessary to check whether the air volume or water volume and water temperature of the condenser are appropriate. And check whether air or other non-condensable gas is mixed in the refrigeration system of the temperature control system of the reactor, or the suction temperature is too high, etc., you should pay attention to observation and detection.
The operator of the reactor temperature control system should also pay more attention to the maintenance of the compressor to avoid damage.
関連推奨品
-
グリコール・チラーの原理分析
1097グリコールのスリラーは冷却剤としてグリコールが付いている産業スリラーです。グリコール・チラーの構造は圧縮機、蒸化器、コンデンサーおよび電気制御システムで構成される通常の産業スリラーのそれと大体 sameas である。...
詳細を見る -
LNEYA給湯器サーキュレーターの適用分野
1221温水循環、これは非常に優れた給湯器で、今では多くの場所で使われている。温水循環装置を使うことで、人々は家庭の温水使用の問題を解決することができる。今日は、温水循環式給湯器の用途をいくつか紹介しよう。
詳細を見る -
防爆型冷蔵庫の別称:金属製冷間加工組立ボックス
1114無錫莞亜LNEYA防爆冷蔵庫は単機式自己折り畳み式極低温加工技術を採用している。SUS304ステンレス鋼線板を採用し、低温箱、水平低温箱、内外箱が分離している。
詳細を見る -
自動車パワーモジュール冷却システムの動作パラメータと動作条件の分析
1164Before choosing, you need to know what factors are related to the operating parameters and working conditions of the automotive power module cooling system. Then, from which aspects? 1. Evaporating pressure and evaporating temperature In the ope...
詳細を見る