How do isolated heating refrigeration circulators deal with inefficiencies?
Heat dissipation is a common problem that causes inefficiencies in isolated heating refrigeration circulators, and it is also a problem that can easily occur. Many isolated heating and refrigeration circulators will have similar problems, so how to deal with such problems.

1. Due to the complex structure of the isolated heating and refrigeration circulator, and each type of equipment may have different principles and operating modes, once a problem occurs, such as the shutdown of an air-cooled electronic fan, heat dissipation problems will occur randomly, or water-cooled cooling. The cold water system of the tower is not smooth, and there will be heat dissipation problems.
2. The heating device jacket and coil (inner coil and outer coil) of the isolated heating refrigeration circulator are all indirectly heated, that is, the cold and hot medium is passed into the jacket and the coil to heat up or cool down. , according to the required production process, set the upper limit of the required working temperature of the reactor.
3. It is not used in accordance with the use requirements of the isolated heating and refrigeration circulator, there is a fixed input voltage and the use requirements of related equipment, and it is not used in accordance with the use requirements of the equipment, such as the voltage is too high or too low, and the condenser and the condenser are not cleaned on time according to the use requirements. Relevant components, failure to increase the refrigerant according to the usage, etc., will reduce the working efficiency of the isolated heating refrigeration circulator.
4. When the temperature is lower than a certain temperature, it will automatically heat up, and if it is higher than a certain temperature, the heating will be stopped, and the power will be automatically cut off and no longer heated, so as to maintain the continuity of the working temperature and time in the kettle. The production process is determined, and attention should be paid when configuring.
There is still a problem that cannot be solved, that is, the failure or damage of components: if you check according to the basic maintenance method, you still cannot find the cause, you can communicate with the manufacturer of the isolation heating and refrigeration circulator, and the quality of after-sales service is also a measure of the relevant equipment manufacturers. sufficient reason for suitability.
If you have any questions about the above content or need to know about the equipment, you can contact us for help sales@lneya.com
関連推奨品
-
展示会プレビュー|2019中国国際自動車テスト品質モニタリング博覧会
1194秋は涼しく、展示会シーズンが再びやってきました!無錫莞雅LNEYA展示会情報をご紹介します:2019中国国際自動車試験と品質管理博覧会展示会開催時間:9月24日から26日まで:9月24日~26日展示...
詳細を見る -
What are the functions of the reactor temperature control system?
1007The reactor temperature control system is equipped with various reactors for high and low temperature reflection of liquid and solid. The temperature control system of LNEYA reactor adopts fully closed circulation pipeline, which is efficient in o...
詳細を見る -
Factors affecting cooling capacity during temperature control of battery test equipment
1208Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For ...
詳細を見る -
冷熱衝撃恒温恒湿試験機の操作手順
1049LNEYA温冷衝撃恒温恒湿試験機の適切なモデルを選択する際には、操作と設置のステップに注意を払う必要があります。ユーザーは設置作業のために十分な準備が必要です。T...
詳細を見る