実験室/生物工学温度制御システムの使用とメンテナンス
1. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual.
2. When moving the laboratory/bioengineering temperature control system, avoid striking the equipment shell, vibrating and damaging or polluting the keypad (function key display).
3. Before use, make sure to regularly check (at least once every two years) whether the equipment is in normal working condition.
4. The laboratory/bioengineering temperature control system shall be stored or used in a clean environment with sufficient fresh air to prevent pollution. There is more than 30cm space around, and the ground is flat and firm. Ensure that the input power is properly grounded when using.
5. Before any repair, maintenance or moving the equipment, the equipment must be turned off and the power supply must be disconnected. The tilt angle of the laboratory/bioengineering temperature control system should not exceed 15 degrees when moving. When the laboratory/bioengineering temperature control system needs to move for a long distance, it is necessary to empty the liquid in the equipment and carefully check the pipe connections to ensure that there is no leakage.
6. When selecting the heat conduction medium, pay attention to whether its upper and lower temperature limits, ignition point, viscosity, freezing point, etc. meet the requirements, and whether it is suitable for the use of the internal pipes of the instrument. Use the heat conduction medium specified by the manufacturer and within the specified pressure range.
7. When selecting the heat transfer medium pipe, the length should be as short as possible and the diameter should be as large as possible. If the diameter is too small, it may cause flow restriction. Do not knot the heat transfer medium pipeline of the high and low temperature all-in-one machine, and check it regularly to avoid material strain (such as fission).
8. Regularly check the liquid sight glass on the side of the equipment to confirm whether the liquid level of the heat transfer medium is at the normal position. Regularly replace the thermal conductivity medium of the laboratory/bioengineering temperature control system. If water is mixed with immiscible oil and water, the mixed liquid will expand after heating, and will spray under high temperature, even causing personal injury.
9. The equipment adjustment parameters must be reset after the new heat conduction medium is filled.
The above are technical maintenance and use matters. If you have other information needs about the equipment, you can leave a message to us, or even send an email to sales@lneya.com
関連推奨品
-
周囲温度を下げることでバッテリーの寿命を延ばすことは正しいのか?
976バッテリーは広い温度範囲で動作するが、高温条件下での充電はできない。充電プロセスは放電プロセスよりもデリケートであり、細心の注意が必要です。極端な低温...
詳細を見る -
高精度半導体定温直列蒸発器の冷凍効果
876装置の異なるモデルの高精度半導体恒温シリーズは、蒸発の選択も異なっており、その後、熱交換器は、高精度半導体恒温にどのような影響を与えるか...
詳細を見る -
耐圧防爆高温および低温1機械メーカーの指示インストールポイント
1186防爆高低温一体型機械が工場から納入された後、目的地に到着してから設置しなければなりません。設置の際に注意すべき点は?防爆高低温一体型機械は、防爆仕様を備えています。
詳細を見る -
新エネルギーモーター試験水冷システムの故障率を下げるには?
1001新エネルギーモーター試験水冷システムは、使用中の使用に注意を払う必要があり、どんなに良い設備を長期間使用しても、多かれ少なかれ何らかの問題が発生する。では、どうすれば使用中の設備の故障率を最小化できるのか。
詳細を見る